Frequently Asked Questions about Fuel Flow Meters
Question number FAQ-0013
Comparison table of specifications for FM-2500 flow indicator and FM-1500 flow indicator.
Comparison table of specifications for FM-2500 flow indicator and FM-1500 flow indicator.
| item | FM-2500 | FM-1500 | Remarks | ||
|---|---|---|---|---|---|
| suitable flow rate detector | FP Series | Available | Available | FP-213S、FP-213、FP-2140H、FP-2240HA、FP-215、FP-2250A | |
| FZ Series | Available | Available | FZ-2100、FZ2200 | ||
| FX Series | Available | × | FX-1110、FX-1120、FX-1130 | ||
| Please contact us regarding old-style detectors. | |||||
| Measurement Module | DF-0400 | Available | Available | For FP series flow detectors. | |
| FZ-0300 | Available | Available | For FZ series flow detectors | ||
| FX-0400 | Available | × | For FX series flow detectors. Cannot be combined with other measurement modules. |
||
| calculation module | FM-0210 | Available | × | Use in combination with flow detectors FP and FZ series (each module). FX series is not applicable. | |
| time measurement | Interval accumulation | s | Available | Available | |
| Total calculation | s | Available | Available | ||
| Rotational measurement (rotational speed, number of rotations) | r/min、REV | Available | × | ||
| Pressure measurement | kPa | Available | Available | Use pressure measurement detectors (FP-2240HA, FP-2250A). | |
| Temperature measurement | ℃ | Available | Available | Using temperature-measuring detectors (FP-2240HA, FP-2250A, FZ-2100, FZ-2200) | |
| Flow measurement | instant | mL/s、g/s | Available | × | |
| mL/min、g/min | Available | × | |||
| L/h、kg/h | Available | Available | |||
| Interval accumulation | mL、g | Available | Available | ||
| L、kg | Available | × | |||
| Total calculation | mL、g | Available | Available | ||
| L、kg | Available | × | |||
| interval average | mL/s、g/s | Available | × | Interval Integrated Flow Rate/Interval Time | |
| mL/min、g/min | Available | × | |||
| L/h、kg/h | Available | Available | |||
| Total average | mL/s、g/s | Available | × | Total accumulated flow rate / Total accumulated time | |
| mL/min、g/min | Available | × | |||
| L/h、kg/h | Available | Available | |||
| jet amount | mm3/st、mg/st | Available | × | ||
| Section Average injection amount |
mm3/st、mg/st | Available | × | ||
| average ejection amount | mm3/st、mg/st | Available | × | ||
| Fuel Density Meter Test* | density | g/cm3 | Available | Available | *When using the flow detector FZ series |
| Temperature conversion setting | Available | Available | 2500: Density calculation at the three specified temperatures. | ||
| 1500: Density calculation for a set temperature at one point | |||||
| Display update time | instant | s | arbitrary | fixed | 2500: Set in the range of 1 to 10 seconds (in 1-second increments) |
| 1500: 1 second | |||||
| Cumulative Measurement Mode | Traffic configuration method | → | 2500: Time accumulation from the start signal to the set cumulative flow rate, rotation accumulation. | ||
| 1500: Time accumulation from the start signal to the set cumulative flow rate. | |||||
| Time setting method | → | 2500: Flow integration and rotation integration from the start signal to the set integration time. | |||
| Flow rate accumulation from the start signal to the set accumulation time. | |||||
| Rotation setting method | → | × | Flow accumulation and time accumulation from the start signal to the set accumulated rotations. | ||
| Voltage output | Flow Rate Measurement | 0~10V | arbitrary value | value selection | 2500: 0-10V/Low-Hi (Low and Hi values are arbitrary) |
| 1500: 0 to 10V / 0 to F.S (F.S values can be selected from 100/200/300/500/1000/1500 (kg/h, L/h)) | |||||
| Pressure (by detector) |
0~10V | arbitrary value | value selection | 2500: 0-10V/Low-Hi (Low and Hi values are arbitrary) | |
| 1500: 0-10V/0-F.S (F.S values can be selected from 200/500/980/1000 (kPa) *Standard: 980 kPa | |||||
| Temperature (by detector) |
0~10V | arbitrary value | fixed | 2500: 0-10V/Low-Hi (Low and Hi values are arbitrary) | |
| 1500: 0 to 10V / 0 to F.S (F.S value fixed at 100°C) | |||||
| Density (FZ only) |
0~10V | arbitrary value | fixed | 2500: 0–10V/Low–Hi (Low, Hi values optional) 0–1g/cm 3 (fixed) | |
| 1500: 0-10V/0-F.S (F.S value fixed at 1g/cm 3) | |||||
| interface | Remote | Available | Available | Option: FM-0200 | |
| RS-232C | Available | ○* | 1500: Measurement values can be printed with the DPU-414 (sold separately). | ||
| GPIB | Available | Available | Option: FM-0263 RS-232C is not available for use when GPIB is stored. | ||
| Digital I/O | Available | × | Option for FX Recess Detector: FM-0361 | ||
| Memory function | Measurement Memory | Available | × | ||
| memory backup | Available | × | |||
| method of representation | → | 2500: LCD with CFL backlight, 320×240 dots | |||
| 1500: Fluorescent display tube (20 characters × 2 lines) Character shape 5×8 dots | |||||
| weight | → | 2500: Approximately 7 kg (when storing 3 modules) | |||
| 1500: approximately 4.2 kg | |||||
| maximum current consumption | → | 2500: External fuse 2A for 40VA or less | |||
| 1500: External fuse 2A for 30VA or less | |||||