RoHS and CE compliant. Speed measurement: 120 P/R, 1200 P/R. Length measurement: 200 P/R.
Excellent ease of use, measurement is possible simply by contacting the roller. Uses a hard urethane rubber coated roller to prevent slippage. For speed measurement, the 1200 P/R model, when used in combination with the TM-4100 series, displays the speed directly, eliminating the need for complex calculations. Measurement is possible from 0.01 m/min. For length measurement, the 200 P/R model, when used in combination with the TM-4300 series, can measure in 1 mm/pulse increments.

Case Studies

Measuring line speed

The line roll speed can be measured in meters per minute.

  • Measuring line speed

* A signal cable is required between the roller encoder and the display unit. (Sold separately)

Roller encoder Signal cable Display
RP-7400 series (speed) RP-0181
Length: 5 m (with crimp terminals on one end)
TM-4100 series

Measurement of rotational speed difference/ratio

It can measure the elongation rate and reduction ratio of steel plates.

  • Measurement of rotational speed difference/ratio

* A signal cable is required between the roller encoder and the display unit. (Sold separately)

Roller encoder Signal cable Display
RP-7400 series (speed) x2 RP-0184
Length: 5 m (with ferrule terminals on one end) x 2
TM-4200 series

Measuring the distance traveled by the conveyor belt

The distance traveled by the conveyor can be measured in 1 mm increments.

  • Measuring the distance traveled by the conveyor belt

* A signal cable is required between the roller encoder and the display unit. (Sold separately)

Roller encoder Signal cable Display
RP-7400 series (length measuring) RP-0184
Length: 5 m (with ferrule terminals on one end)
TM-4300 series

Specification

Electrical characteristics Number of output pulses for speed 120, 1200 P/R
For measuring length 200 P/R
Output waveform 2 phase square wave
Duty cycle 50 ±25%
phase difference 90 ±45°
Output voltage
(When supplying DC12 V)
“Hi”: +10 V or more
“Lo”: +0.5 V or less
Output method Totem pole (load resistance 470 Ω or more)
option RP-0701: Emitter output
RP-0702: Collector output
RP-0703: Open collector output
Power supply DC12V ±5% (100 mA or less)
Environmental characteristics Operating temperature range 0 to +50 °C
(No freezing or condensation)
Storage temperature range -10 to +65 °C
(No freezing or condensation)
Operating humidity range 35~93%RH or less
(No freezing or condensation)
Protection class IP40 (when using cables RP-0181 / RP-0182)
Weight 約400 g
Mechanical properties Speed range 0–600 m/min
(The speed range varies depending on the conditions of the object being measured.)
Roller material Core metal: Aluminum
Rubber: Urethane coating (hardness A90)
Roller circumference 200 mm
Allowable shaft load Radial: 20 N
Starting Torque 1 mN・m
Moment of inertia 0.6 kg・ cm²
Vibration resistance 19.6 m/
X/Y/Z directions (150 mins each), 10-150 Hz sweep, 20 cycles
Shockproof 196 m/
X/Y/Z ± both directions (6 directions) 3 times each (total 18 times), half sine wave, action time 11 ms
Mounting holes (position) ⌀10 mm x2
20 mm spacing
  Accessories Instruction manual (1 copy)
One connector (RM12BPE-5S: manufactured by Hirose Electric Co., Ltd.)
Compatible Cables
(option)
RP-0181 (Single-sided crimp terminal M3) 5m: For connecting TM-4100 series Digital Tachometer
RP-0184 (Single-ended ferrule terminal) 5 m: For connecting to TM-4300 series reversible counters
Compatibility indicator for speed TM-4100 Series Digital Tachometer
For measuring length TM-4300 Series Reversible Counter
Outline drawings Specification
price Main unit  
Option 出力オプション:RP-0701 / RP-0702/RP-0703:各
ケーブル:RP-0181(5 m)
ケーブル:RP-0184(5 m)

※ RP-0181は、最大延長10 mまで。(受注生産5 m延長ごと¥3,300(税抜)増し)

* Roller encoders (for length measurement) may accumulate errors in measurement values due to installation conditions, roller slippage, roller wear, etc.
* The TM-4300 series reversible counter has a correction function, which can compensate for outer circumference errors caused by roller wear, etc.
*When measuring travel speed (m/min) using the RP-7400 1200 P/R and FV-1500 combination, please set the display unit to "USER".