DF-2200

External dimensions: 170(W) x 49(H) x 120(D) mm. It's small and lightweight at approximately 800g, making it easy to carry in a car.
It comes standard with CAN output, which is essential for actual vehicle measurements. Instantaneous flow rate, temperature, and pressure are output in real time to a CAN logger or other device.
Connect the LC-0860 CAN interface cable (sold separately) to the CAN communication connector located on the rear panel of the DF-2200 vehicle-mounted fuel flow meter.
By increasing the speed of internal sampling and performing an exponential averaging function to the analog output, the system outputs averaged data from transient measurements as desired. By pre-entering a reference density value into the DF-2200, real-time mass flow rate conversion is performed. The HOLD function, auto-stop function (optional), and display data averaging processing have been significantly improved.
It supports a wide range of test vehicles, from passenger cars to trucks. *AC adapter (optional) supports AC 100-240V.
(Excluding the FP-5000 series high-resolution specifications and the FP-5150 series)

Features

1. Compact design suitable for in-vehicle use

External dimensions: 170 (W) x 49 (H) x 120 (D) mm. It's small and lightweight at approximately 800 g, making it easy to carry in a car.

  • 1. Compact design suitable for in-vehicle use. No. 1
  • 1. Compact design suitable for in-vehicle use No. 2

2. Standard equipped with CAN output.

We have included CAN output, which is essential for actual vehicle measurements, as a standard feature.
Instantaneous flow rate, temperature, and pressure are output in real time to a CAN logger or similar device.

CAN system configuration

Connect the LC-0860 CAN interface cable (sold separately) to the CAN communication connector located on the rear panel of the DF-2200 vehicle-mounted fuel flow meter.

  • CAN System Configuration No. 1
  • CAN System Configuration No. 2

3. Enhanced measurement functions

By increasing the speed of internal sampling and using an exponential averaging function for analog output, the system outputs averaged data from transient measurements as desired.
By pre-entering the reference density value into the DF-2200, real-time mass flow rate conversion can be performed.
The HOLD function, auto-stop function (optional), and display data averaging process have been significantly improved.

  • 3. Enhanced measurement functions

4. Power supply compatible with DC 10-28V

We support a wide range of test vehicles, from passenger cars to trucks.
* Compatible with AC 100-240V with an optional AC adapter.

  • 4. Power supply compatible with DC 10-28V No. 1
  • 4. Power supply compatible with DC 10-28V No. 2
    LC-0082 Battery Power Cable (Included)

System Configurations

Compatibility detector

  • Compatible detector No. 1
    (Excluding the FP-5000 series high-resolution specifications and the FP-5150 series)
  • Compatible detector No. 2

Specification

General specifications

Power supply Battery connection: DC 10-28V
When using an AC adapter (optional): AC 100-240 V 50/60 Hz
Power consumption 28 VA or less (at DC12 V)
Usage environment Indoors, inside the car
high Altitude below 2000 m
Operating temperature range 0 to 50 °C *The operating temperature range for the AC adapter is 0 to +40 °C
Storage temperature range -10 to 60 °C
Operating humidity range 5-80%
Storage humidity range 5-85%
External dimensions 170 (W) x 49 (H) x 120 (D) mm
Weight 約800 g
safety IEC61010-1: Overvoltage Category II, Ground Protection Class II, Pollution Degree II
• When using the optional AC adapter
Applicable standards Low Voltage Directive 2014/35/EU Standard EN61010-1 (when using an AC adapter)
EMC Directive 2014 / 30 / EU Standard EN61326-1
RoHS Directive 2011 / 65 / EU Standard EN IEC 63000
Compatibility detector FP series (excluding the FP-5000 series high-resolution specifications and the FP-5150 series), MF-3200
Accessories Battery power cable (equivalent to LC-0082), rubber feet, instruction manual

Option

Model name name Remarks
DF-0221 Auto-stop function Accumulation Auto Stop
DF-0222 RS-232C communication function *When DF-0222 is selected, CAN communication will be disabled, and simultaneous selection with DF0225 is also not possible.
LC-0860 CAN interface cable CAN communication cable connector specifications (D-Sub / 9-pin / male connector (main unit side))
DF-0223 Remote box for DF  
DF-0224 Output speed enhancement function High-speed output is possible, reducing the standard output time from 10 ms to 1 ms.
DF-0225 CAN cumulative value output function *Cannot be selected simultaneously with DF-0222 RS-232C.
PS-P20023 AC adapter *Power cable must be purchased separately.
  AC adapter power cable
(For use within Japan)
For VPS-P20023 VM1391-VM1700 (2 m) for domestic use
CT-0673 Panel mounting brackets Common for CT-6700
CT-0675 Protective handle Common for CT-6700
CT-0676 Light-blocking hood Common for CT-6700