Skip to main content

Select your region & language

Global

Region

Volumetric Flow Detector
made-to-order
FP-5000シリーズ

FP-5130 Series
FP-5130 Series
FP-5130 Series
FP-5140 Series
FP-5150 Series
FP-5150 Series
FP-5150 Series

Achieves accurate flow measurement from low flow to high flow across a wide range.

The evaluation of the engine has shifted from steady-state tests to transient tests such as exhaust gas modes and performance evaluations to determine the mode-integrated fuel economy. An assessment of fuel consumption characteristics during transients is required. To accurately capture the flow rate changes during transients with good responsiveness, the pulse resolution has been finely tuned and made high-resolution.
Additionally, in the case of alcohol fuels, the flow rate increases due to the lower calorific value. To measure this, alcohol standard compatibility and wide-range capability have been achieved.

Features

1. Capture minute flow changes

Achieved a pulse resolution up to 20 times greater than conventional methods. Realized 0.0005 mL/pulse. *For the FP-5130 series.

  • 1. Capture minute flow changes

Example: Instantaneous mass flow measurement at engine start-up

 
Case: Comparison Test of Injector Accumulation Variation

Case: Comparison Test of Injector Accumulation Variation

 

FP-5000 Series Flow Sensor Installation Instructions

Wide range from low flow to high flow

We offer a wide range of flow detectors. One detector can accommodate a variety of applications from idling to wide-open throttle (WOT).

Flow Measurement Range Table by Application

  • Supports a wide range of applications from idling to wide-open throttle.
    Supports a wide range of applications from idling to wide-open throttle.
  • Adding wide range & high-resolution type
    Add wide range and high resolution type.

3. Compact and Space Saving

The flow detector, filter (accessory), temperature and pressure sensor unit, and Fuel Density Meter can be connected together, achieving space-saving.

  • img-fp5000-12

4. Alcohol Standard Compliance

The flow detector now supports alcohol as standard.
In the previous models, alcohol support was optional, but it has been made standard in the FP-5000 series.
With the acceleration towards carbon neutrality, corrosion resistance, which was not required for fossil fuels, is now necessary for alcohol blended fuels, making it usable for those as well.

  • 4. Alcohol Standard Compliance

System Configurations

  • img-fp5000-11

Specifications

Standard type Small flow type Medium flow type Large flow type
Type (Series) FP-5130 Series FP-5140 Series FP-5150 Series
  Specification No.1 Specification No.2 Specification No.3
Usable liquid Gasoline, diesel, kerosene, alcohol biofuel, general petroleum-based hydraulic oil (Note 1)
Measurement range Flow Rate Measurement FP-5131 / 5132:0.05 to 60 L/h
FP-5133 / 5134:0.05 to 108 L/h
(Note 2)
FP-5141 / 5142:0.3 to 300 L/h
FP-5143 / 5144:0.3 to 600 L/h
FP-5151 / 5152: 1 to 1440 L/h
Accuracy Flow Rate Measurement ±0.0009 L/h or less
(0.05 to 0.18 L/h)
±0.5 % of reading
(0.18 to 108 L/h)
±0.2% of the reading value ±0.5 % of the reading value
Pressure loss Below 8 kPa
(40 L/h <gasoline>)
Below 2 kPa
(<60 L/h <gasoline> )
7.5 kPa or less
(<500 L/h <diesel> )
Operating temperature Liquid 0~+65 °C 0~+65 °C 0~+65 °C
Environment 0~+65 °C 0~+65 °C 0~+65 °C
Connection diameter Size IN:Rc3/8(※3)
OUT:Rc3/8(※3)
IN:Rc3/8(※3)
OUT:Rc3/8(※3)
IN:Rc1/2
OUT:Rc1/2
Pressure resistance 1 MPa 1 MPa 3.4 MPa
Temperature and Pressure Block EH-0830A EH-0830A EH-0850A
Measurement range Temperature 0~+100 °C 0~+100 °C 0~+100 °C
Pressure 0 to 1 MPa 0 to 1 MPa 0 to 1 MPa
Accuracy Temperature Pt100 Class A Pt100 Class A Pt100 Class A
Pressure ±0.5 %F.S ±0.5 %F.S ±0.5 %F.S
Weight 約3.5 kg 約5 kg 約13.5 kg
Accessories Instruction manual, line filter (EH-1130 or EH-1150),
mounting brackets (mounting brackets tailored to options are included for FP-5130 / 5140 series)
Cable Option specifications FP-0015 (5 m), FP-0016 (10 m), FP-0017 (20 m)
Applicable flow meter Various digital flow meters
FM-2500A / DF-0400A (*High resolution specifications (FP-5132, 5134, FP-5142, 5144), and not compatible with FP-5152)
DF-2200 (*High resolution specifications (FP-5132, 5134, FP-5142, 5144), and not compatible with FP-5151, 5152)
FM-3100 / FM-0311A
Filter Element
  filter EH-1130 EH-1130 EH-1150
element EH-0031A EH-0031A EH-0051A

The Volumetric Flow Detector FP series may experience fluctuations in the instantaneous flow rate values of the flow meter under the following usage conditions. Please be cautious.

  1. If the inlet pressure of the flow detector is lower than the pressure loss.

  2. When using the exit side of the detector open to the atmosphere.

    (Note 1) Please consult your nearest sales office.

    (Note 2) Flow meter measurement range starting from 0.02 L/h is also available. Please consult your nearest sales office.

    (Note 3) Optional fittings (SAE fittings) are also available. Please consult your nearest sales office.

Options

Model name Product name Remarks
FM-0312 FD connector options Add an FD connector to FM-0311A.
FP-0015 5 m flow signal cable Cable for connection to FM / DF series flow meters
FP-0016 10 m flow signal cable
FP-0017 20 m flow signal cable
FP-0025 Temperature signal cable 5 m Cable for connection to FM / DF series flow meters
FP-0026 Temperature signal cable 10 m
FP-0027 Temperature signal cable 20 m
FP-0035 Pressure signal cable 5 m Connection cable for FM/DF series flow meters
FP-0036 Pressure signal cable 10 m
FP-0037 Pressure signal cable 20 m
FD-0011 Density signal cable 5 m Cable for connection to FM series flow meter
FD-0012 10 m density signal cable
FD-0013 density signal cable 15 m
EH-0830A Temperature and Pressure Sensor Unit for FP-513X and FP-514X The FP-513X and FP-514X are common
EH-0830A is a combination product of EH-0081 and EH-0082A.
EH-0850A FP-515X temperature and pressure sensor unit for FP-515X
EH-0731 Mounting bracket for FP513X (1 unit) 1 UNIT: Flow Detector (including Line Filter)
EH-0732 FP513x mounting bracket (2 units) 2UNIT: Flow Detector + Fuel Density Meter or Temperature Pressure Sensor Unit
EH-0733 FP513x mounting bracket (3 UNIT) 3UNIT: Flow Detector + Fuel Density Meter + Temperature and Pressure Sensor Unit
EH-0741 Mounting bracket for FP514X (1 unit) 1 UNIT: Flow Detector (including Line Filter)
EH-0742 Mounting bracket for FP514X (2 units) 2UNIT: Flow Detector + Fuel Density Meter or Temperature Pressure Sensor Unit
EH-0743 Mounting bracket for FP514X (3 UNIT) 3UNIT: Flow Detector + Fuel Density Meter + Temperature and Pressure Sensor Unit
EH-0730A Common stand for FP513X and FP514X When using the stand, please use it at a vibration of 9.8 m/s 2 or less.