Skip to main content

Select your region & language

Global

Region

Portable Vibration Meter
NEW
VW-3100

The VW-3100 is a Portable Vibration Meter that realizes "listening", "measuring", and "judging" necessary for on-site vibration measurement in one device.
It solves problems with vibration sensing technology and signal processing technology provided by Ono Sokki, a manufacturer of measuring instruments.

Four points of the VW-3100

1. Never miss machine abnormalities
Simultaneous display of acceleration, speed, and displacement.
Prevents oversight and maximizes inspection efficiency.

2. Be the "ear" of the expert
Accurately identify abnormal sounds with a variable filter.
Helps in the transmission of diagnostic techniques using a stethoscope.

3. Bring back the "evidence" from the field
Simultaneously perform vibration measurement and recording.
Enables precise diagnosis in the office.

4. Supports ISO evaluation, route inspection, and trend management
Strongly assists vibration measurement with various functions such as ISO 20816 evaluation and trend management.

Features

Application examples

For those struggling with technical inheritance.

For those struggling with technical inheritance.

Reproducing the "ear" and "intuition" of experts with the "listening function"
Quantifying the five-sense inspection into numbers and data

For those aiming to digitize inspection operations.

For those aiming to digitize inspection operations.

Smart modernization of measurement and data trend management using a Portable Vibration Meter.

To the person in charge of handling noise issues.

To the person in charge of handling noise issues.

The cause of the abnormal sound is triggered by vibration phenomena.
"Converting vibrations into sound and comparing them with past vibrations will expedite the investigation of the cause."

For those who are having trouble discovering abnormalities.

For those who are having trouble discovering abnormalities.

The VW-3100's unique feature, the 'V3 band', reliably captures signs of failure that are often overlooked.

VW-3100 Product Introduction Video

List of Functions

Standard Functions

Vibrometer mode

In addition to four types of display modes (Single, Triple, Trend, List), it is equipped with a listening function and a band-pass filter as standard.

  • Vibrometer mode

Measure three vibration values simultaneously.

Issue :
Despite regular inspections, the machines still break down.
The machine's malfunction hasn't been detected.

Solution :
To identify machine malfunctions, it's necessary to measure three vibration values (acceleration, velocity, and displacement). These values can be calculated and displayed simultaneously using the V3 band. This allows for accurate identification of abnormalities and improves work efficiency.

Can extract abnormal sounds and signs of deterioration.

Issue :
I can't tell which one is the strange noise.
There is no difference in vibration values between normal and abnormal conditions.

Solution :
A variable bandpass filter allows you to freely set the frequency range and extract only specific frequency bands.

Can hear the vibrating sound.

Issue :
The experience of skilled professionals and the sounds heard with a stethoscope
It cannot be shared or passed on to other workers.

Solution :
The sensor signal can be converted into sound and listened to. By narrowing the frequency range with a variable filter, it becomes easier to detect abnormal noises.
It can also be used as a tool to listen to "vibrational sounds" instead of a stethoscope.

Easily switch between four measurement screens.

By changing perspectives in measurement, understanding of phenomena advances, leading to increased measurement efficiency.

  • Single: Check vibration value, rotation speed, and equipment name.

  • Trend: Understanding the fluctuations of vibration values.

  • Triple: simultaneously measuring three vibration values.

  • List: Grasp measurement values at once.

  • Easily switch between four measurement screens.

Optional Functions

VW-0310 Equalizing Function (options)
VW-0310 Equalizing Function (options)

Issue :
It's difficult to distinguish between different sounds from a variety of other sounds, like a skilled professional can.

Solution :
The vibration sound can be increased or decreased in 1/1 octave band increments. By emphasizing unwanted sounds and reducing them, you can recreate the "hearing" of an expert and share key nuances.

VW-0320 Recording and Comparison Function (options)
Just press REC→START for detailed analysis in the office.
Just press REC→START for detailed analysis in the office.
Recording function

Issue :
Bringing a data recorder is a hassle. Gathering people on-site to check for unusual noises is also troublesome.

Solution :
You can record while taking measurements and performing inspections. You can then take the recordings back to the office, listen to the vibration sounds again, and perform detailed analysis using software like O-Solution. It can also be used for technology transfer.

Register recorded data
Register recorded data
Comparison Function

Issue :
I can't tell if the vibration sound has changed.
I want to compare it to the sound when an abnormality occurs.

Solution :
You can switch between vibration sounds measured on-site and pre-recorded vibration sounds and compare them in real time.
Furthermore, using the V3 band makes it easier to determine whether or not there is an abnormality.

VW-0330 Filter Expansion Function (options)
HPF/LPF cutoff frequency [Hz] (the shaded area is expanded)
HPF/LPF cutoff frequency [Hz] (the shaded area is expanded)

Issue :
We want to accurately capture the abnormal phenomena.
I want to take measurements without being affected by noise.

Solution :
In addition to the standard bandpass filter, you can select even finer frequency ranges.

VW-0340 ISO Evaluation and Judgment Function (options)
You can immediately tell if the threshold has been exceeded.
You can immediately tell if the threshold has been exceeded.

Issue :
I want to move away from maintenance that relies solely on experience.
I want to make appropriate decisions while monitoring vibration values.

Solution :
You can choose between absolute value evaluation and relative value evaluation as your evaluation method.
The equipment's condition can be assessed using evaluation criteria that comply with ISO and JIS standards.

Vibration Diagnosis Assist Tool

VW-0360 Vibration Diagnosis Assist Tool (options)

This is software that manages the measurement conditions and acquired data of the vibration meter.
By creating measurement conditions and evaluation criteria on the software and sending them to the Portable Vibration Meter, the efficiency of inspection work can be improved. Furthermore, by smoothly visualizing the trends of vibration values and comparing them with evaluation criteria, it leads to the efficiency of maintenance work.

  • VW-0360 Vibration Diagnosis Assist Tool
    VW-0360 Vibration Diagnosis Assist Tool
  • Measurement data from the VW-3100 can be sent to a PC.
    Measurement data from the VW-3100 can be sent to a PC.

Making the VW-0360 even more convenient
VW-0350 Assist Tool Communication Function (options)

Using the ID list created by linking equipment information and measurement conditions on the software, vibration values can be measured on-site while confirming the equipment information. Even for route inspections involving multiple pieces of equipment, data acquisition can be done efficiently and reliably.

*The use of VW-0350 requires VW-0360.

  • VW-0350 Assist Tool Communication Function
    VW-0350 Assist Tool Communication Function
  • Send the measurement conditions created on the PC to the VW-3100.
    Send the measurement conditions created on the PC to the VW-3100.

System Configurations

We introduce the available sensors and system configurations.

  • System Configurations

Specification

Sensor Input

Signal Input Built-in preamplifier accelerometer (NP-3000 series, etc.)
External voltage signal input (switchable)
Number of Channels 1 Channel
Input Connector BNC (C02 type), waterproof (when sensor is connected)
Input Voltage Range ±5 V
Constant Current Drive (CCLD) Drive voltage: +23 V to 26 V
Constant current value: 4 mA ± 25 % (25 ℃)
Absolute Maximum Input Voltage ±30 V(peak)
TEDS IEEE 1451.4 Ver.0.9 / 1.0
Measurement Range Setting 0.100 m/s² ~ 50000 m/s²
(The measurement range setting varies depending on sensor sensitivity)
Unit Calibration Function Select from m/s² or EU
EU Type mV/EU, V/EU, EU/V, EU/mV
Sensor Sensitivity Setting 000.0100 ~ 999.9999
Analog Filter Low cut
(high-pass filter)
OFF/1 Hz/3 Hz/10 Hz
at fc (※) –3 dB (± 1 dB), –18 dB/Oct
High cut
(Low pass filter)
OFF/1 kHz//10 kHz
at fc (※) –3 dB (± 1 dB), –18 dB/Oct
Input Frequency Response 3 Hz to 15 kHz ± 0.5 dB, 1.5 Hz to 20 kHz ± 3.0 dB
80 Hz standard

External Signal Input

Function Rotation speed input / Trigger input switch
Number of Channels 1 Channel
Input Connector 2.5 mm mini jack
Number of Rotational Pulses 0.5 to 360 P/R (set in increments of 0.5)

Analysis Section

A/D Conversion Resolution 24 bit
sampling frequency 64 kHz
Number of Bands 3 bands
digital filter High-pass filter / Low-pass filter OFF / 10 Hz / 30 Hz / 50 Hz / 100 Hz / 300 Hz / 500 Hz /
1 kHz / 3 kHz / 5 kHz / 10 kHz / 20 kHz
at fc (※) -3 dB (± 1 dB), -48 dB/Oct
Vibration Severity Filter ISO 2954:2012 compliant filter equipped
(High-pass filter 10 Hz, Low-pass filter 1 kHz)
Measurement Frequency Range Acceleration 1.5 Hz~20 kHz
Velocity 3 Hz~3 kHz
Displacement 3 Hz to 500 Hz

Computation Section

Measurement Items RMS Time constant effective value
Time constant 8 ms / 16 ms / 32 ms / 63 ms / 125 ms / 250 ms / 500 ms / 630 ms / 1 s
PEAK maximum absolute value of the time waveform
P-P twice the value of the peak
CF Ratio of maximum PEAK to maximum RMS (PEAK / RMS) at 500 ms intervals.
EQpeak RMS's √2 times value
EQp-p Double value of EQpeak
(EQp-p can only be measured when [Mode] is [Displacement] under [V3 band condition])
Calculated Items Instantaneous value / Maximum value / Average value (calculated simultaneously for each measurement item)

Display Section

Display 4.3-inch transmissive LCD (with capacitive touch panel)
Display Update calculated value Select from 500 ms / 1 s

External Interface Department

LAN Measurement conditions and receiving and sending measurement data
(VW-0350, VW-0360 options required)
USB Bus Powered Function Power supply only (not compatible with USB PD).
SD card Response card SD, SDHC, SDXC maximum 64 GB

Output Section

Analog Output AC/THR Connector AC output / THR output (switching)
DC Connector DC Output
output impedance 50 Ω
AC/THR Output Output Target AC : Signal after operation in any one band
THR : Signal just before digital processing
Output Connector 2.5 mm mini jack
Output Voltage Range ±5 V
offset voltage within ± 20mV
DC Output Output Target Effective value calculation data for the selected band 1.
Output Connector 2.5 mm mini jack
Output Voltage Range 0 to +5 V
offset voltage within ± 20mV
PHONE Output Output Target The signal before or after passing through a band-pass filter in any given band.
Output Connector 1 x 3.5 mm mini jack (for connecting earphones/headphones with a 3.5 mm stereo mini plug (3 poles))
Maximum Output 18 mW (representative value when the load is 20 Ω)
Volume Adjustment 20 levels
CAL Output Output Signal (AC) Sine wave 160 Hz, amplitude 1.0 V (peak) ± 3%
Output Signal (DC) 0.707 V ± 3 % (excluding DC offset voltage)
output gain ×1, ×2, ×5, ×10, ×20, ×50, ×100

General Specifications

Battery Type 4 AA alkaline batteries (LR6) or 4 nickel-metal hydride rechargeable batteries (HR6)
Continuous Operation Time LR6: Over 4 hours (measured in the default vibration mode of the main unit, using NP-3331C, analog output, headphone output OFF)
Measured with Panasonic's EVOLTA NEO
USB Bus Powered Input Voltage Range DC 4.75 V to 5.25 V
Absolute Maximum Input Voltage DC 6.5 V
Current Consumption When supplied with 5 V, below 900 mA.
Mobile Battery Only those that meet the above-mentioned power specifications will operate.
Clock Backup Battery lithium secondary battery
Operating Temperature Range -10 °C to +50 °C (excluding the battery)
Operating Humidity Range 10 to 90% RH (non-condensing)
Storage Temperature Range -20 °C to +60 °C (excluding the battery)
Storage Humidity Range 10 to 90% RH (non-condensing)
Outline Dimensions 104 mm(W) × 223 mm(H) × 42 mm(D)
Weight Approximately 625 g (main unit only, including battery).
Waterproof and dustproof IP54 (when the NP-3331WC connection, headphones, external input terminal cap, main body bottom cover, and battery cover are attached)
Applicable Standards CE marking
EMC Directive: 2014/30/EU Standard EN 61326-1:2021
RoHS Directive: 2011/65/EU Standard EN IEC 63000
Accessories Simple instruction manual / AX-501 one unit / SD card / BNC cap

*fc: cutoff frequency

Accessories

  • Accessories for VW-3100: VW-0010

    Accessories for VW-3100
    VW-0010

    Neck strap 1 piece
    Hand belt 1 piece

  • Soft Carrying Case CC-0024

    Soft Carrying Case
    CC-0024