DG-4320/DG-4340

DG-4320
DG-4320
DG-4340 (with comparator)
DG-4340 (with comparator)

The DG-4320/DG-4340 digital gauge counters receive signals from linear gauge sensors and precisely measure and display dimensions and displacements. With added new functions necessary for measurement, such as calculation and condition saving, they excel in in-line measurement in production environments.
* The display example for DG-4340 (in red) shows the case when the comparator fails.
When the result is OK, it will be displayed in green, just like the DG-4320.

Features

  • Ono Sokki Compatible with all linear gauge sensors (except GS-3800B series)

  • Features include multiplier switching, panel condition memory, and MAX, MIN, and RANGE calculations.

  • Compatible with 12V power sensors (optional).
    It also counts single-phase pulse signals from devices such as rotation detectors and signals from encoders.

  • Equipped with a 3-channel comparator function, it can determine whether a component or product passes or fails (DG-4340).
    When the comparator is activated, the backlight of the display screen changes to red to clearly indicate this.

System Configurations

  • System Configurations

Connection and communication

The BCD output of the DG-4320/DG-4340 is, in principle, equivalent to the pin assignment and connector of the DG-4140.
However, due to the inclusion of new features, pins that were previously unused in older models are now being used. Also, the comparator output terminal found on the DG-4240/DG-4280 is absent.

Pin Signal content Pin Signal content
DG-4120 DG-4140 DG-4240 DG-4280 DG-4320/DG-4340
1 1 x 10⁻⁶ BCD output 19 4×104
2 2×100 20 8×104
3 4×100 21 N.C Start input Lower output Preset1 Start input
4 8×100 22 N.C Stop input OK output Preset2 Stop input
5 1 x 10 1 BCD output 23 N.C N.C Upper output Preset3 Display switching input 1
6 2×101 24 N.C N.C N.C Preset4 Display switching input 2
7 4×101 25 Polarity output +
8 8×101 26 Polarity output -
9 1 x 10² BCD output 27 D.P 0.00 Decimal point 1
10 2×102 28 D.P 0.000 Decimal Point 2
11 4×102 29 N.C 1 x 10⁵ BCD output
12 8×102 30 Error output
13 1 x 10³ BCD output 31 Hold input
14 2×103 32 Reset input
15 4×103 33 Busy Input
16 8×103 34 N.C Comparator gate input Comparator gate input N.C Comparator gate input
17 1 x 10⁴ BCD output 35 Print command output
18 2×104 36 common

Case Studies

Pass/fail determination using a 3-channel OK/NG comparator function.

By detecting the height of the screw, you can check how tightly the screw is fastened.
Equipped with three OK/NG comparators, it can handle three different sizes of screws.

  • Pass/fail determination using a 3-channel OK/NG comparator function.

Pass/fail determination using a 3-channel OK/NG comparator function.

In inspecting the flatness of a part, a sensor is placed against the object and rotated once.
You can easily measure flatness by looking at the RANGE value (MAX-MIN).

  • Pass/fail determination using a 3-channel OK/NG comparator function.

Length measurement using pulse counter function

The length of paper or steel plates is measured using a rotary encoder attached to the feed roller.
By using the multiplication switching function and factor setting function, you can convert the pulse output from the encoder into length.

  • Length measurement using pulse counter function

Automatic detection using BCD output function

This function determines whether the dimensions of the machined parts are within the specified range. The BCD output can be imported into a PLC, and sorting can be performed based on the measured values.

  • Automatic detection using BCD output function

Recommended BCD External Signal Input/Output Interfaces

Output signal interface circuit

(BCD output, polarity output, decimal point output, error output, print command output)

Output format Open collector output
Withstand voltage Max. 24 V
Maximum sink current Max. 30 mA
Residual voltage Max. 0.5 V
  • Output signal interface circuit No. 1

(Start input, Hold input, Reset input, Busy input, Comparator gate input)

Input Low-Level Voltage 0 ~1.4 V
Input High-Level Voltage 3 to 5.25 V
Input Impedance 1 kΩ or more
  • Output signal interface circuit No. 2

Specification

Model name DG-4320 DG-4340
Display method LCD display, segment and dot-matrix combined display, 2-color backlight, 6-digit display.
Display range 0 to ±199999 (When 0.5 µm resolution is selected, only 0 or 5 is displayed for the first digit)
Compatible sensors Our linear gauge sensors (excluding GS-3800 series) *1
Our sensors (encoders, etc.) with 2-phase and 1-phase square wave voltage output types.
Sensor power output: DC 5 V ±10%, 200 mA
Resolution switching Choose from 0.5 µm, 1 µm, or 10 µm *2
Input signal Two-phase phase difference square wave, one-phase square wave (supported by switching internal settings)
Input frequency range DC ~300 kHz
Display numeric type Instantaneous value, Max value, Min value, RANGE value (Max value - Min value)
Calculation function Offset function, Factor function, Multiplication function, Decimal point position change function
Digital output BCD output, update time 10 ms, open collector output (positive/negative logic switchable)
Comparator 3-stage, semiconductor relay system
Upper and Lower comparators
Switch OK/NG comparator settings.
The backlight changes to red when in operation.
Panel condition memory function The setting parameters are stored internally in the counter (4 conditions).
External dimensions / weight 72(W) × 72(H) × 114(D) mm/approx. 320 g
Power supply voltage AC 100~240 V
Operating temperature range 0 °C to +40 °C Approx. 6 VA (at 100 VAC)
Storage temperature range −10 ℃~+55 ℃
price    
Option ・DG-0430 電源供給オプション(DC 12 V 150 mA)
・AA-8101 BCDケーブル 3 m(DA-4130 D/A変換器用)
・AA-8107 BCDケーブル 3 m(片側オープン)
・AX-2050N 電源ケーブル 3 m(AC100V用)

*1 If you intend to connect the DG-4300 series with the BS-102 series (discontinued), please contact us.
*2 If you select an encoder as the sensor type, the units and decimal points will not be displayed.
(The decimal point can be displayed using the "Decimal Point Position Setting Function".)

最終更新日:2023/07/27