Skip to main content

Select your region & language

Global

Region

Digital Flow Meter
FM-3100

Achieving high-speed output in response to changes in transient flow.

In the field of engine development, high precision in low flow rate measurement and evaluation of fuel consumption characteristics during transients are required.
The FM-3100 is a digital flow meter that outputs measurement data at high speed when combined with various detectors (FP, FX, FZ series, Fuel Density Meter).

Features

1. High-speed response output 1 ms (Analog / CAN)

By capturing transient flow changes, it can output analog output and CAN output at an update rate of 1 ms.
Compared to the previous model FM-2500A's 100 ms, the response is faster, making it suitable for confirming the rise of instantaneous flow and measuring fuel flow during transient operation.

  • High-speed response output 1 ms (analog / CAN)
  • Injector Injection Flow Measurement
    Injector Injection Flow Measurement

High-speed response → Changes in fuel injection flow rate can also be expressed.

2. Enhancement of CAN external control New features

The functionality to control the FM-3100 externally using CAN has been enhanced.

Set accumulated time via CAN communication.

Set accumulated time via CAN communication No.1

To change the Auto Stop total accumulated time from an external source, RS-232C communication was required, but it can now also be changed via CAN communication.
Since accumulated operations (such as Start and Stop) have been possible with CAN from the beginning, it is now possible to consolidate the necessary external communication to only CAN for applications where the accumulated stop time is switched for continuous testing, thereby simplifying the system.
Command 06: Accumulated time setting has been added. It is now possible to set the accumulated time from an external source. The Auto Stop accumulated time setting, which could only be changed through direct operation and RS-232C, can now be done via CAN.

Set accumulated time via CAN communication No.2

Using the CAN In ID (default value: 0x601), set the value,
and output command 06: set the accumulated time to the FM-3100 to configure the accumulated time.

Easily perform repeated measurements.

01 Start
02 Stop
03 Hold
04 Reset
05 Reset + Start ​NEW​

CAN command

The input command for CAN has been updated to include 05: Reset + Start command,
making it easier to perform repeated measurements.

3. Supports various range pressure sensors New feature

You can now freely set the input voltage range and pressure range. You can measure pressure using your own pressure sensor.

4. Simultaneous output of volumetric flow and mass flow from analog output New feature

Simultaneous output of volumetric flow rate and mass flow rate from analog output.

Regarding the analog output of the module specifications, it has become possible to use not only OUTPUT 1 but also OUTPUT 2 for flow measurement. This allows for simultaneous analog output of volumetric flow and mass flow.

5. Improve the reliability of the measurement process (optional) New feature

To ensure the reliability of measurement data, a password lock function will be added to the settings of each parameter that affects the measurement data.
Additionally, the change history of some parameters will be automatically recorded. This allows for immediate identification of when a particular setting was in place in the event of a configuration error.

password lock function

password lock function

Changes to factors in the FP series and changes to the output scale that affect measurement data will require a password.

Change history function

Change history function

If the Factor of the 'FM-0311 FP Module' or the Zero CAL and Low Flow Cut of the 'FM-0321 FZ Module' are changed, the date and time of those changes, as well as the new values, will be automatically saved for later confirmation.

Video

Example: Instantaneous mass flow measurement at engine start-up

 
Example: Comparison of measurement values with exhaust gas analyzers.

Example: Comparison of measurement values with exhaust gas analyzers.

 

FP-5000 Series Flow Sensor Installation Instructions

System Configurations

  • Example of device configuration

Specifications

General Specifications

Power supply voltage AC 100 V to 240 V ± 10%
Power consumption Up to 80 VA (when connecting two units of FM-3100 and FP-2140S)
Operating temperature range 0 ~ +50 ℃
Operating Humidity Range 10 to 85% (non-condensation)
Storage Temperature Range -10 ~ +60 ℃
Storage Humidity Range 10 to 85% (non-condensation)
Outline Dimensions 240(W) × 99(H) × 297(D) mm *excluding protrusions
Weight approximately 3 kg
Applicable Standards CE marking (FM-0311A or FM-0311A + FM-0312)
Low Voltage Directive 2014/35/EU standard EN61010-1
EMC Directive 2014/30/EU standard EN61326-1
RoHS Directive 2011/65/EU standard EN IEC 63000
Applicable detectors FP Series / FD-5110 / FX Series / FZ Series
※ Please add modules (sold separately) for various detectors.
Accessories AC power cable, FM-0012 analog output conversion adapter (D-Sub - BNC cable 0.5 m), user manual

 

FM-0311A module for FP use + FM-0312 FD connector option

Applicable detectors FP-213, FP-214, FP-214H, FP-2140H, FP-2240HA
FP-215, FP-2250A
FP-213S, FP-2130S, FP-2140S
FP-3130, FP-3132
FP-3140, FP-3142, FP-314H
FP-3150, FP-3152, FP-315
FP-4135
FP-5131, FP-5132, FP-5133, FP-5134
FP-5141, FP-5142, FP-5143, FP-5144
FP-5151, FP-5152
FD-5110
EH-0830A, EH-0850A, EH-0081, EH-0082A
※For inquiries about old products, please contact us.
Calculated items Instantaneous flow, section cumulative flow, section average cumulative flow, cumulative flow, cumulative average flow, instantaneous injection amount in the cylinder, section average injection amount in the cylinder, cumulative average injection amount in the cylinder, temperature converted density value, instantaneous pressure, instantaneous density, Fuel Density Meter temperature.
Calculation cycle 1 ms
Forward flow, forward flow + reverse flow mode When calculating cumulative flow and section cumulative flow, it is possible to switch between forward flow and forward flow + reverse flow modes.
In forward flow mode, the reverse flow is calculated as zero flow (0 L/h).
In forward + reverse flow mode, the reverse flow is calculated as negative flow.
When calculating instantaneous flow, regardless of the mode, the reverse flow is displayed as negative flow.
Temperature measurement Capable of signal input from the temperature sensor and computation.
Pressure measurement Capable of signal input and calculation from the pressure sensor.
Density measurement with a Fuel Density Meter. Density and temperature measurement is possible with the Fuel Density Meter.
Display accuracy ±1 count for the pulse weight of the input frequency.

FM-0321 Module for FZ Use

Applicable detectors FZ-2100, FZ-2200A, FZ series low flow type (made to order)
Calculated items instantaneous flow, section integrated flow, section average integrated flow, integrated flow, integrated average flow, instantaneous chamber injection amount, section average chamber injection amount, integrated average chamber injection amount, temperature converted density value, instantaneous density, instantaneous temperature
Calculation cycle 1 ms
ZERO calibration A function that adjusts the output value to zero when there is no flow.
LowFlowCut a function that sets flow rates below a certain level to 0 L/h
Display accuracy ±1 count for the pulse weight of the input frequency.
Temperature measurement Capable of signal input from the temperature sensor and computation.

FM-0331 Module for FX Use

Applicable detectors FX-1110, FX-1120, FX-1130
Calculated items instantaneous flow, section cumulative flow, section average cumulative flow, cumulative flow, cumulative average flow, instantaneous chamber injection amount, section average chamber injection amount, cumulative average chamber injection amount
Calculation cycle 100 ms
Density setting Range: 0.0001–5.0000 g/cm3
Initial value: 1.0000
Liquid Level Static Time (Delay Time) Range: 2 to 99 s (initial value: 2 s)
Charge Level Range: 0 to 95% (Initial: 0%)
Overflow signal Relay output contact voltage capacity (DC 48 V, AC 120 V), contact current rating (500 mA or less)

Options

Model name Product name Remarks
FM-0311A FP module Dedicated to FP series detectors.
FM-0312 FD connector options Add an FD connector to FM-0311A.
FM-0321 FZ module Dedicated to FZ series detectors.
FM-0331 FX module Dedicated to FX series detectors.
FM-0341 blank panel for FM-3100
FM-0351 Digital flow meter Chinese option Chinese representation
FM-0200 Motor box for FM for FM-3100
PE3534394 RS-232C adapter Convert from the dedicated connector of the FM-3100 main unit to an RS-232C D-sub 9-pin connector (0.1 m).
FM-0012 FM-3100 Analog Conversion Adapter D-Sub - BNC
FM-0011 Mounting bracket for FM-3100  
LC-0860 CAN cable FM-3100 CAN cable (2 m)