Skip to main content

Select your region & language

Global

Region

Automatic air release tank
MF-015

It is difficult to accurately measure the flow rate of fuel passing through a flow detector when there is air contamination. The MF-015 automatic air vent tank is an automatic air vent device that uses a precision float valve, which, when incorporated into the measurement flow path, automatically releases the entrained air into the atmosphere.

Case Studies

Air Bleeding of Flow Detector Installation during Actual Vehicle Test No.1

Air bleeding during the installation of flow detectors in actual vehicle testing.

In the actual vehicle testing of diesel engines, the air bleeding process after installing the flow detector took a long time, and it was difficult to determine whether the air had been bled out.
By installing our air bleeding tank along with the flow detector, we can reduce the time for the air bleeding process and improve testing efficiency.

 

Specification

usable liquid Gasoline, diesel, kerosene
maximum flow Approximately 100 L/h
tank capacity 0.7 L
pressure resistance 200 kPa
Air Bleeding Method Automatic air release valve
joint Hose nipple R1/4 inner diameter Φ 6 mm, outer diameter Φ 9 mm, bamboo joint (suitable for both IN/OUT).
Weight approximately 1.8 kg
Outline Dimensions Φ93(W)×212(H) mm
Price  