Volumetric Flow Measurement System

FP-5130 Series
FP-5140 Series
FP-5150 Series
FP-2130S
FP-2140S
FP-3130S
FP-3140
FP-4135
Digital Flow Meter DF-2200 Vehicle-Mounted Fuel Flow Meter
Digital Flow Meter FM-3100 Digital Flow Meter

Measure instantaneous and cumulative fuel flow rates during on-stage and in-vehicle fuel economy tests.

Volumetric flow refers to the volume of fluid flowing per unit time.
By installing the Volumetric Flow Detector FP series in the flow path and combining it with the digital flow meter FM-3100 or DF-2200, volumetric flow measurement can be easily performed.
Since the volume of fluid expands and contracts due to temperature changes, temperature management during measurement is important.

series composition

1. About the Volumetric Flow Detector

Features of volumetric flow detectors combined with digital flow meters.

  • Continuous measurement over a long period

  • low pressure loss

  • Responding to dangerous places.

  • can be mounted on a vehicle

You can choose from the following four types of detectors.

Standard Type FP-5000 Series

Standard Type FP-5000 Series

  • Achieved a pulse resolution up to 20 times greater than conventional methods.

  • A wide range of flow rates is lined up.

  • Can be connected as one with various options, achieving space-saving.

  • Standard compatible with alcohol fuel.

Low pressure loss type FP-2130S / FP-2140S

Low pressure loss type FP-2130S / FP-2140S

  • pressure loss compensation type that drives the flow detector with a motor to keep the free piston in a neutral position
  • Achieves reading value accuracy of ±0.2% across the entire flow measurement range.
Explosion-proof Type FP-3000 Series

Explosion-proof Type FP-3000 Series

internal pressure explosion-proof

  • Detector + Air Supply Unit + Internal Pressure Protection Monitoring Panel

  • Available for use in dangerous areas Zone 1 and Zone 2.

  • Low pressure loss type is also selectable.

pressure-resistant explosion-proof

  • Detector + Relay Box

  • Available for use in dangerous areas Zone 1 and Zone 2.

Vehicle-mounted type FP-4135

Vehicle-mounted type FP-4135

  • Compact and high-temperature resistant, convenient for vehicle use.

  • super wide range with a flow ratio of 1:2000

  • Improvement of vibration resistance

  • Standard compatible with alcohol fuel.

  • FP Series Flow Rate Range List
    FP Series Flow Rate Range List

2. About digital flow meters

Digital flow meters are available in two types: a standard type equipped with various flow detectors and connections to a Fuel Density Meter, and a compact, lightweight vehicle-mounted type.

FM-3100 Digital Flow Meter

FM-3100 Digital Flow Meter

  • High-speed response output 1 ms (analog, CAN)

  • Compatible with various detectors (FP series, FX series, FZ series)

  • Equipped with a density value temperature correction function, addition and subtraction functions between modules, and various calculation functions.

DF-2200 Vehicle-mounted Fuel Flow Meter

DF-2200 Vehicle-mounted Fuel Flow Meter

  • Compact body convenient for in-vehicle use.
  • Wide power supply DC 12V / 24V vehicle compatible
General Specifications Digital Flow Meter FM-3100 On-vehicle Fuel Flow Meter DF-2200
suitable detector

FP Series / FD-5110 / FX Series / FZ Series
*Please add the corresponding modules (sold separately) for each detector.

FP-4135・MF-3200・FP-2130S・2140S・
FP-5131/5133・FP-5141/5143
power supply voltage AC 100–240 V ±10 % 80 VA or less
(when connecting two units of FM-3100 and FP-2140S)
DC 10 to 28 V, below 28 VA
Operating Temperature Range 0~+50 °C 0 to +50 °C (Note: The operating temperature range for the AC adapter is 0 to +40 °C)
Operating Humidity Range 10 to 85% (non-condensing) 5~80 %
Outline Dimensions 240 (W) × 99 (H) × 297 (D) mm (excluding protrusions) 170 (W) × 49 (H) × 120 (D) mm (excluding protrusions)
Weight approximately 3 kg approximately 800 g
Applicable Standards CE marking (FM-0311A/FM-0312)
Low Voltage (LVD) Directive 2014/35/EU Standard EN61010-1
EMC Directive 2014/30/EU Standard EN61326-1 Class A Group 1
RoHS Directive 2011/65/EU Standard EN50581
Low Voltage (LVD) Directive 2014/35/EU Standard EN61010-1 (when using AC adapter)
EMC Directive 2014/30/EU Standard EN61326-1
RoHS Directive 2011/65/EU Standard EN50581
Measurement Items Temperature・Pressure・Time
Module for FP・FD: Instantaneous volumetric flow rate, Instantaneous density
Module for FZ: Instantaneous mass flow rate, Instantaneous density
Module for FX: Instantaneous weight flow rate
Instantaneous flow rate, temperature, pressure, cumulative flow, time
Accessories AC power cable, FM-0012 analog output conversion adapter
(D-Sub, BNC cable 0.5 m), instruction manual
DC power cable with clamp

 

Related products

FP-5000 Option: Temperature and Pressure Sensor Unit

FP-5000 Series Volumetric Flow Detector

FP-5000 Series Volumetric Flow Detector

In volumetric flow measurement, it is important to measure the temperature at the time of measurement along with the flow rate.
We offer a temperature and pressure sensor unit that can be connected to the Volumetric Flow Detector FP-5000 series.

Temperature Sensor for FP-4135 as standard

FP-4135 On-board Volumetric Flow Detector

FP-4135 On-board Volumetric Flow Detector

It is equipped with a temperature sensor as standard.
Temperature measurement: -30 °C to +100 °C
Temperature accuracy: Class A

Temperature sensor for Low pressure loss type

low pressure loss type

When adding temperature and pressure sensors to the FP-2130S and FP-2140S, you can purchase the EH-0081 temperature sensor and EH-0082 pressure sensor separately, and install them in the flow path as part of your work.
It is also possible to install the temperature and pressure sensors using the block for adding temperature and pressure sensors (made to order) to the detector.

explosion-proof type

When adding temperature and pressure sensors to the explosion-proof type FP-3000 series, explosion-proof products are required. (Made to order)

Principle of Measurement

Four pistons arranged radially in the flow detection section repeat reciprocating motion due to the liquid flowing from the inlet to the outlet. At this time, the movement of the pistons is converted into rotational motion by a crankshaft and transmitted to the magnetically coupled rotational detection section. The rotary encoder in the rotational detection section generates pulse signals corresponding to the amount of movement of the pistons.

  • Measurement Principle No.1
  • Measurement Principle No.2

System Configurations

  • System Configurations

Case Studies

The Importance of Temperature Management in Flow Measurement

Temperature changes in the piping flow path affect flow measurement.
Here, we will intentionally vary the fluid temperature and introduce its impact on flow measurement.

When the fuel is cooled in heat exchanger ①, the volumetric flow rate measured by FP-4135 initially increases due to liquid contraction caused by cooling. Subsequently, as the T2 temperature stabilizes, the volumetric flow rate measured by FP-4135 stabilizes but decreases. This is due to the increased density of the cooled liquid (making it harder to flow) and the cooling and contraction of pipes and fittings in the flow path, which increases the pressure loss.

Changes in fuel temperature affect the results of volumetric flow measurements. When measuring volumetric flow, it is important to use temperature control devices to keep the fluid temperature constant and to insulate the pipes to block the influence of external temperature changes.

Our High-Precision Fuel Flow Measurement System features a piping configuration that suppresses temperature changes and ensures reliable, high-precision flow measurement.

  • The Importance of Temperature Management in Flow Measurement_No.1

test conditions

  • Keep the fuel flowing at a constant flow rate.

  • Initially, no cooling water is flowed through heat exchanger ①.

  • At the 10-second mark of the time series graph, a sudden flow of cooling water at 15 °C is introduced to heat exchanger 1.