Skip to main content

Select your region & language

Global

Region

フリー ユーティリティ プログラム(販売終了製品)

Free Sample Program / Driver File

  • This utility program is provided free of charge to customers using compatible products. Changes and additions to this program are generally allowed, but please understand that we cannot provide support for it.

  • We have prepared PDF files that describe the overview of each program. We recommend that you read them before downloading the programs.

  • Please pay attention to the compatible OS. To download the program, customer registration is required. New customers should click on [New Registration], while existing customers should click on [Password Login]. If you have forgotten your password, please follow the instructions on the displayed page.

  • Registration of the serial number is required for each model, so please understand this in advance.

Disclaimer

  • Support is generally not provided for free programs.

  • We are unable to provide support for operational issues arising from incompatibilities (commonly referred to as compatibility issues) between free software programs and specific devices.
  • Furthermore, the company shall not be liable for any damages or disadvantages incurred by customers due to malfunctions. Please be aware of this in advance before using our services.
  • The free program is provided as-is. Ono Sokki is not obligated to correct any errors, malfunctions, or defects in the free program for any reason, including changes to its specifications.

For AU series analog signal processing unit

This sample program and utility is compatible with Windows® 7 32-bit.

  Configuration file name explanation
1 Configuration file for AU-2100 sensor amplifier unit This is a configuration file for installing a driver to control the AU-2100 via USB.
2 AU-2200 Microphone Amplifier Unit Configuration File This is a configuration file for installing a driver to control the AU-2200 via USB.
3 AU-2300 Configuration File for Vibration Amplifier Unit This is a configuration file for installing a driver to control the AU-2300 via USB.
4 Configuration file for AU-3100/3200 filter unit This is a configuration file for installing the driver to control AU-3100/AU-3200 via USB.

*Only the registered serial number is valid. You cannot log in with other serial numbers. New registration is required for each product.

CF-4500 FFT Comparator

* Utility programs for the CF-4500 FFT Comparator
“Comparator Logger” and “Shape Comparator Data Maker” are
available for download on the CF-4500 User Page.

* On the CF-4500 FFT Comparator User Page,
Excel Macros: "Set upper and lower limits for tracking data" "Hard-copy screen data to printer"
You can also download it.

CL-2400 Non-contact Thickness Gauge

This sample program is compatible with Windows 2000 and Windows XP operating systems.

  Sample Program Name explanation
1 CL-2400 Non-contact Thickness Gauge Simple Monitor Program 
(Excel Macro)
Data communication is performed between the computer and the CL-2400 using RS-232C, and the collected data is displayed in Excel.
Overview of Simple Monitoring Program for Non-Contact Thickness Gauge CL-2400 (PDF 0.2 MB)

For digital gauge counters DG-3250/3350 (3000 series)

  Product name explanation
1 DG-3000 Series
Dynamic Link Library for Digital Gauge Counter
User Manual
(DLL)
The software is included as standard with the product, but if you create your own, please refer to this instruction manual.
User Manual for Dynamic Link Library GaugeC48.dll (DLL) for DG-3000 Series (PDF 0.1 MB)

For HG-4370 Digital Gauge Counter

This sample program is compatible with Windows 2000 and Windows XP operating systems.

  Sample Program Name explanation
1 Simple Monitor Program for HG-4370 Digital Gauge Counter (Excel Macro) Data communication is performed between the computer and HG-4370 using RS-232C, and the captured data is displayed in Excel.
Overview of the simple monitoring program for Digital Gauge Counter HG-4370 (PDF 0.2 MB)

LA-1200/1300/4300 series sound level meter

This sample program supports Windows 95/98/Me/2000/XP operating systems, excluding EXCEL macros.
EXCEL macros are compatible with EXCEL 97.

  Sample Program Name explanation
1 Data Memory Read Convert the measurement data from the sound level meter's internal memory into a text file and save it on a computer.
2 Measurement Condition Settings You can set the measurement conditions of the sound level meter from a computer. The measurement conditions can be saved to the specified panel condition of the sound level meter.
3 Reading instantaneous value (LP) data Read instantaneous values from the sound level meter at intervals of 100ms or 200ms and save them as a text file on the computer.
4 Display & Remote You can display and operate the sound level meter on the computer screen.
5 New Environmental Standards Road Traffic Noise Secondary Processing
(Excel 97 Macro)
Convert the automatically measured text data into a table format for Excel 97 and create a graph.
  sound level meter Overview of Sample Program for LA-1200/1300/4300 Series (PDF 2.0 MB)

LA-1440/4440 Series sound level meter

  • Connect the LA-1440/4440 sound level meter to a PC using an RS-232C cable or a USB cable.

  • This sample program and utility are compatible with Windows® XP SP2 and later, as well as Windows® 7 in both 32-bit and 64-bit versions.

  • To use this program, the following files are required in addition to this program.
    Please follow the instructions to obtain the files and install them properly.

    • Microsoft .NET Framework 2.0c

    • Microsoft .NET Framework ×× Japanese Language Pack
      (Please adjust ×× to match the version of Microsoft .NET Framework you have installed)

Additionally, a USB driver is required when connecting via USB. Please download the 'USB driver configuration file' along with the sample program. For more details, please refer to the PDF file below.

  Sample Program Name explanation
1 Measurement Condition Settings You can communicate with the sound level meter to display its panel condition on the PC and set the panel condition from the PC to the sound level meter.
2 Remote Program You can communicate with the sound level meter to display its screen on a PC and remotely control some of its functions.
3 Memory Read This is a program that communicates with a sound level meter to read and save the contents of its manual memory and auto memory to a PC.
4 USB driver configuration file This is a utility file for configuring USB driver settings for communication via USB.
  Overview of the sample program for LA-1440 Standard sound level meter and LA-4440 Precision sound level meter (PDF 7.7 MB)

LA-2110/2111/5110/5111/5120 Series sound level meter

This sample program is compatible with Windows 95/98/Me/2000/XP.

  Sample Program Name explanation
1 Data Memory Read 
(Visual Basic 6.0)
Convert the measurement data from the sound level meter's internal memory into a text file and save it on a computer.
2 RTA display & loudness read
(Visual Basic 6.0)
You can display octave data as a bar graph on the computer screen and operate the sound level meter. Additionally, you can save the loudness values and octave data in text format on the computer.
Note: This program is for use with a sound level meter equipped with the options listed below. Functionality will be limited depending on the installed options.
  • Real-Time Octave (LA-0563/0564)
  • Loudness Option (LA-0565)
sound level meter Overview of Sample Program for LA-2000/5000 Series (PDF 0.1 MB)

LA-3560/3570/3260 Series sound level meter

  • The LA-3560/3570/3260 sound level meter does not require a program to read memory data. By connecting to a computer via a USB cable, direct access to the sound level meter's SD card can be achieved. The files recorded on the sound level meter's SD card are in CSV format (files recorded with the LA-0354 sound recording function are in WAVE format).

  • Among the programs listed below, (1) LpData and (2) Remote Display are programs for reading data through RS232C communication with a computer. The AX-5022 RS-232C cable (2m) is used to connect the sound level meter to the computer's RS-232C connector.

  • This sample program and utility are compatible with Windows 2000/XP/Vista/7, excluding Excel macros. Excel macros are supported from Excel 97 onwards.

  Sample Program Name explanation
1

LpData - Instant Value (LP) Data Load (Visual Basic 6.0)

Read instantaneous values from the sound level meter at intervals of 100 ms or 200 ms, and save them as a text file on the computer.
Sample program for sound level meter LA-3000 series Instantaneous value (Lp) reading overview (PDF 0.1 MB)
2

Remote Display - Display & Remote (Visual Basic 6.0)

You can display and operate the sound level meter on the computer screen.
Sample program for sound level meter LA-3000 series display & remote overview (PDF 0.1 MB)
3 New Environmental Standards for Road Traffic Noise Data Secondary Processing Excel Macro The data automatically measured by the sound level meter will be converted into an Excel table format to create a graph.

*Only the registered serial number is valid. You cannot log in with other serial numbers. New registration is required for each product.

LA-5560/5570/2560 series sound level meter

  • The LA-5560/5570/2560 sound level meter does not require a program to read data from its built-in memory. Files can be opened directly via a USB cable connection (excluding the LA-0554 sound recording function and the LA-0555 advanced comparator function).

  • Among the programs listed below, the first three from the top are programs for communicating with a computer via RS232C to read data. The data recorded on the sound level meter's SD card can be directly read into the computer in CSV file format from the SD card. Additionally, by connecting the sound level meter to the computer with a USB cable, the data recorded on the SD card can similarly be directly read in CSV file format.

  • This sample program & utility is compatible with Windows 2000/XP OS, excluding EXCEL macros. It has also been confirmed to work on Windows 7.
    EXCEL macros are compatible with EXCEL 97 and later.

  Sample Program Name explanation
1 Instant Value (LP) Data Load (Visual Basic 6.0) Read instantaneous values from the sound level meter at intervals of 100ms or 200ms and save them as a text file on the computer.
2 Display & Remote (Visual Basic 6.0) You can display and operate the sound level meter on the computer screen.
3 RTA display & loudness read (Visual Basic 6.0)
(excluding LA-2560)
You can display octave data as a bar graph on the computer screen and operate the sound level meter. Additionally, you can save loudness values and octave data in text format on the computer. It is also possible to save only the octave data without performing loudness calculations.
Note: This program is for the sound level meter equipped with the options listed below, and is for main unit software version 2.0 and later. Functionality will be limited depending on the option configuration.
・LA-0551 1/1 Real-time octave analysis function / ・LA-0552 1/3 Real-time octave analysis function
4 New Environmental Standards Road Traffic Noise Data Secondary Processing (Excel Macro) The data automatically measured by the sound level meter will be converted into an Excel table format to create a graph.
5 file conversion This is software that converts FFT analysis data saved from the LA-5560/5570/2560 sound level meters into a CSV file format that can be read by the DS-2000 series data station.
Note: This program is for use with main software version 2.0 or later. This program is for the sound level meter equipped with the LA-0553 spectrum monitoring function option.
sound level meter Sample Program & Utility Overview for LA-2560/5560/5570 Series (PDF 0.1 MB)

This sample program is compatible with Windows XP and LabVIEW versions 7.1 and 8.0.

  Sample Program Name explanation
1 Remote Control Program for LabVIEW 7.1 or 8.0 This is a program (vi) that remotely controls the LA-5560/5570/2560 via RS-232C on LabVIEW. It writes data to a text file at intervals of approximately 150 milliseconds.
Note: Additional LabVIEW software is required.
Overview of the sample program for sound level meter series LA-2560/5560/5570 (LabVIEW 7.1 or 8.0) (PDF 1.5 MB)

For SR-5300 Real-Time Analyzer

This sample program is compatible with Windows 95/98/Me/2000/XP.

  Sample Program Name explanation
1 Data Loading (Visual Basic 6.0) Convert the measurement data from the internal memory of the SR-5300 into a text file and save it on the computer.
Overview of Sample Program for Real-Time Analyzer SR-5300 (PDF 0.1 MB)

TM-3100 Series Digital Tachometer

This sample program is compatible with Windows 2000 and XP operating systems.

  Sample Program Name explanation
1

TM-3100 Series
Simple Monitor Program for Digital Tachometer

Data communication will be conducted between the computer and the TM-3100 series tachometer using RS-232C.
Overview of Simple Monitor Sample Program for TM-0350 RS-232C Card (PDF 0.1 MB)

*Only the registered serial number is valid. You cannot log in with other serial numbers. New registration is required for each product.

For TH-5100/TS-2700/3200 Series Digital Torque Meter

This sample program is compatible with Windows 2000 and Windows XP operating systems.

  Sample Program Name explanation
1&2

TS-2700/3200 Digital Torque Meter Simple Monitor Program
(Excel Macro)

Data communication is performed between the computer and the TS-2700/3200 using RS-232C, and the captured data is displayed in Excel.
Overview of Simple Monitoring Program for TS Series (PDF 0.1 MB)
3 TH-5100 Digital Torque Meter Simple Monitor Program
(Excel Macro)
Data communication is performed between the computer and the TH-5100 using RS-232C, and the captured data is displayed in Excel.
Overview of the Simple Monitoring Program for the TH Series (PDF 0.1 MB)

for VR-6100 vibration level meter

This sample program is compatible with Windows 95/98/Me/2000/XP.

  Sample Program Name explanation
1

Screen Output (Visual Basic 6.0)

The vibration level meter VR-6100 can save the display on its LCD screen as a bitmap file in Windows BMP format, and the saved bitmap file can be re-displayed on a personal computer screen.
2

Condition (Measurement Conditions) Memory Settings (Visual Basic 6.0)

The measurement conditions of the vibration level meter VR-6100 can be set from a computer. The measurement conditions can be saved to the specified panel conditions (C1 to C9) of the vibration level meter VR-6100.
3 Remote Control (Data Memory Transfer) (Visual Basic 6.0) You can perform remote control operations (display and setting changes) for the vibration level meter VR-6100 from a computer, as well as transfer memory data.
4 Real-time Octave (Visual Basic 6.0) You can remotely control the real-time option functions of the vibration level meter VR-6100 from a computer (display and setting changes), as well as transfer memory data.
Note: This program requires the built-in option (VR-0653 or VR-0654).