Torque Meter Frequently Asked Questions
Question number FAQ-1257
Differences between the TH Series Magnetic Phase Difference Method and the "New" Magnetic Phase Difference Method: Part 2 - "Maximum Response Frequency" and "Update Time"
| Magnetic phase difference system | "New" Magnetic Phase Difference System | |
|---|---|---|
| Applicable models | SS / MD / DD / EZ / DSTP series | TH Series |
|
Maximum response frequency Analog output |
10 Hz |
Standard: 100Hz |
| SS/MD/DD/EZ/DSTP In the series Set using the time constant. Standard: 63 ms (TS-2700) 16 ms (TS-3200) Option: 1 ms |
TH In the series It can be set using both the time constant and the cutoff frequency. ・Time constant Standard: 1.6 ms Option: 0.16 ms • Cutoff frequency: Standard: 100 Hz Option: 5 kHz |
|
![]() |
![]() |
|
|
Update time time to measure |
Updated every 4 ms (Optional 1 ms response time available) |
Update every 50 μs |
![]() |
![]() |
* 1. The responsiveness can be changed by setting the time constant of the torque calculator. Furthermore, the mechanical responsiveness is limited by the moment of inertia and spring constant of the torque meter and the test specimen connected to it.
● The mounting hole dimensions, center height, and shaft dimensions are the same for both the SS series and the TH series.
Last updated: 2012-10-15