Magneto-Electric Rotation Detector
Question number FAQ-0858
Method of fixing for MP-9810 / MP-9830
(1) Mounting bracket
Please use non-magnetic materials and secure it to prevent movement due to vibrations. Tighten with the nuts of MP-9810 / MP-9830. A tightening torque of 15 to 20 Nm is recommended.
(2) Alignment
Align the alignment mark (▲) of the MP-9810 / MP-9830 to be almost in the center of the gear's tooth tip. Please install it so that the gear's axis and the detector are at a right angle. The distance from the gear should be about 0.5 mm at m0.5 and about 1 mm at m1.


Last updated: 2025-03-27