Fuel Flow Indicator Frequently Asked Questions
Question number FAQ-0819
Can the AutoStop function be configured using CAN communication on the FM-3100?
While the AutoStop function cannot be configured via CAN communication, data can be read via CAN communication if the AutoStop conditions are manually set on the FM-3100 beforehand. CAN communication is limited to data acquisition and Start, Stop, Hold, and Reset commands. To configure the AutoStop function and perform all measurements online, please use RS-232C communication.
- Cumulative flow rate measurement using AutoStop function via RS-232C communication

- Configured via RS-232C
AutoStop type (time, flow rate, etc.)
AutoStop values (cumulative time, cumulative flow rate, etc.) - Start command via RS-232C communication
- Once the measurement is complete, the data will be read via RS-232C communication.
- Configured via RS-232C
- Cumulative flow rate measurement using AutoStop function via CAN communication

- Set the AutoStop type and value manually in advance.
- Start measurement via CAN communication.
- Once measurement is complete, the data is read via CAN communication.
Last updated: 2021-12-27