CF-5200 Frequently Asked Questions
Question number FAQ-0485
Is it possible to control the signal output so that the power spectrum is constant (with the acceleration of the vibration machine being constant)?
It is possible with AMP CONTROL within the sign sweep sequence control function.
If the feedback signal is small during the sweep (chB waveform) and the control signal requires a voltage above the set voltage of the signal output AMP (e.g., 1V), it outputs the set voltage (1V) and steps up to the next frequency.
It is necessary to set the AMP's setting voltage higher than the control target voltage.
Only sine sweep can be controlled by feedback.
Chapter of the relevant instruction manual
Analysis of the 4.5 amp control function
Last updated date: 2006-01-16