Question number FAQ-0148

How often are the measurements from capacitive thickness gauges and displacement gauges updated?

■ CL-5600/5610 Capacitive Thickness Gauge

The timing for updating measurement values is as follows. When measuring objects moving at high speed, measurements will be taken intermittently.

Displayed value0.5 s
Analog output terminals
(A-OUT <CL-5610>, THICK <CL-5600>)
20 ms
Analog output terminals
(SENSOR-A, SENSOR-B)
The sensor signal is output directly after adjustment, so the response frequency range is 4,000 Hz.
RS-232Cmin 50 ms
(This may vary depending on the PC's capabilities and the program.)
BCD output20 ms

■ VT-5210/5220/5710/5720 Capacitive Displacement Gauge

Since it only processes analog signals, it is defined by the response frequency range.

Response frequency range4,000 Hz(VT-5210/5710)
10,000 Hz (VT-5220/5720)