Digital Gauge Frequently Asked Questions
Question number FAQ-0103
Gauge Stand (ST-022, ST-0230, ST-044B)
■Specifications ・ Compatible Gauge
| Gauge Stand Model Name | ST-022 | ST-0230 | ST-044B | |
|---|---|---|---|---|
| Applicable Gauge | Gauge Sensor Model Name | BS-1210 *1 BS-1310 *1 GS-7710A *1 GS-7710NA *1 |
GS-1713A/1730A GS-1813A/1830A GS-3813B/3830B GS-4713A/4730A GS-4813A/4830A GS-6713A/6730A GS-6813A/6830A |
GS-5050A/5100A GS-5051A/5101A |
| Reference |
Stem outer diameter Φ 8 mm Stroke 10 mm |
Stem outer diameter Φ 15 mm Stroke 13/30 mm |
Stem outer diameter Φ 15 mm Stroke 50/100 mm |
|
| Table dimensions (mm) | 80 × 85 | 105 ×105 | ||
| Applicable stem outer diameter (mm) | Φ8~10 | Φ15 | Φ15~20 | |
| table material | Ceramic (grooved) | |||
| Measurement surface flatness | 1μm | |||
| Surface roughness of the measurement surface | 0.4S wrap finish | |||
| Base (width × depth mm) | 100 ×160 | 130 × 200 | ||
| measurable depth (mm) | 約 59 | 約 60 | 約 73.5 | |
| measurable height (mm) | 約 115 | 約 210 | ||
| mass (kg) | 4.1 | 4.2 | 7.5 | |
When using a linear gauge sensor with a stem outer diameter of 8 mm mounted on gauge stands ST-0230 or ST-044B, the AA-891 (optional: stand bushing / inner diameter 8 mm, outer diameter 15 mm) is required.
■ ST-022 outline drawing
■ ST-0230 outline drawing
■ST-044B outline drawing
The overall dimensions will be one size larger than ST-022.
Last updated date: 2019-03-12