Fuel Flow Indicator Frequently Asked Questions

Question number FAQ-0020

How do I perform the initial setup when using the FP-2250A flow detector with the FM-2500 flow indicator?

When using the FM-series for the first time, you must configure the following items on the FP-flow detector during initial setup.
Similarly, if you change the FP-flow detector you are using, you will need to configure it in the same way.

Initial setup method when using the FP-2250A flow detector with the FM-2500 flow indicator.

 

<Caution>

  • This is how to set up the standard specifications. Please note that the settings will differ for custom specifications.
  • This is how to configure the settings from the factory default.
  • This setting measures instantaneous flow rate (volume). For settings for other measurements, please refer to the instruction manual.
  • The display refresh time is 1 second (factory default). Please refer to the instruction manual for instructions on how to change this setting.

 

(1) Set the date. (※This step is unnecessary if the date is correct) →Click here for instructions on how to set the date.

 

(2) Set the following in order: ① detector, ② factor value, ③ encoder pulse, and ④ pressure sensor settings.

 

<Operating Procedure>

 

1. SETUPPress (MENU) to display the settings screen.

data set >>Please select the slot you wish to use. If you wish to use multiple slots, each slot requires separate configuration.upordownin

Slot1: DF0400Select

ENTERPress this button to display the settings menu.

 

2. The DF-0400 Setup menu will be displayed.

upordownin

SensorSelect

ENTERPress this button.

 

3. The Sensor setup menu will be displayed.

upordownin

SelectSelect

ENTERPress to display the detector selection list.

 

4. Display the list of detectors to configure.

>> Select the detector to use
(The currently selected sensor has been reversed.)

 

 

5. Specify the detector to use.

(The detector used is the FP-2250A.)upordownThen select FP225X

ENTERPressing this button confirms the detector settings.

 

6. Set the factor value.

upordowninFactorSelect,ENTERWhen you press
The higher-order digits of the factor value are inverted.

>>Set the factor value as indicated on the detector's nameplate or inspection report.

leftorrightPressing this button will move the inverted digit.upordownPressing this button will increase or decrease the inverted value.

[Example of a 4-digit factor value]
If the factor value is 4 digits, set the most significant digit to 0: 09824 (Example setting)

 

7. Factor Value Determination

ENTERPressing this button confirms the setting of the factor value.

 

8. Encoder pulse settings

If the encoder pulse is displayed (set) as 120*10, no further settings are required.
→ Proceed to step 10. If the setting (display) is anything other than 120*10,
If you want to set it to "120", follow these steps:upordowninEncoder PulseSelect

ENTERPressing this button will display a list of pulse count options.
9. Select from the list of options.

upordownSelect 120 * 10

ENTERPressing this button confirms the encoder pulse.

The number of decimal places displayed will start from 0.0.
*If you want to reduce the number of digits by one, please select 120.

【reference】

 

10. Pressure sensor settings

upordowninPress SensSelect

ENTERPressing this button will display a list of rated pressure options.
upordownSelect 980

ENTERPressing this button will set the rated pressure.

 

11. MENUPressing this button will bring up the measurement display screen.

Last updated: 2007-06-18