Portable 2-channel/4-channel FFT Analyzer
CF-9200A/CF-9400A

CF-9200A
CF-9200A
CF-9200A
CF-9400A
CF-9400A
CF-9400A
CF-9400A

The function of innovation is wrapped in a tough body.

The CF-9200A/CF-9400A (CF-9000A series) is an all-in-one portable-style FFT analyzer. It allows full operation of the FFT analyzer using only the hard keys and capacitive touch panel on the main unit, without the need for a separate PC for analysis.
Equipped with a newly developed 24-bit A/D converter and a high-performance front end with 100 kHz analysis capability, it enables easier and more reliable analysis of noise and vibrations emitted by mechanical devices such as plant piping, pumps, motors, automobiles, railways, and home appliances compared to conventional models. It also responds to field solutions requiring FFT analysis, such as resonance and frequency characteristic analysis of mechanical structures using electromagnetic exciters and impulse hammers.

Features

Quick, light, and intuitive operation with keys & touch panel Quick

Examples of touch panel operations for the CF-9400A and the key operation section for the CF-9200A.

The CF-9200A/CF-9400A performs basic operations of the FFT analyzer such as display, measurement, stop, recording, and reading with large hard keys. It guarantees reliable and speedy operation.

Settings for the number of waveform displays and zooming in and out of the X and Y axes can be intuitively operated using swipe and pinch gestures on the touch panel. It can be easily changed to the desired scale.

Continuous 8 hours ※ cordless operation, battery replacement possible while power is ON Mobility

The measuring device is in a state with two battery packs attached.

The CF-9200A/CF-9400A is equipped with two large-capacity lithium-ion rechargeable batteries, enabling cordless operation for up to 8 hours of continuous use.

Additionally, it features a hot-swap mechanism that allows for battery replacement while the power is ON, enabling measurement tasks to continue without interruption or reconfiguration during analysis or recording work. The built-in battery can also be charged while in operation ※.

※ Approximately 7-8 hours to full charge with power ON.
Approximately 7-8 hours with power OFF (at an ambient temperature of 20 °C).

FFT・RTA・Vibration Control & Simultaneous Recording Versatile

Example of analysis screen for CF-9200A/CF-9400A.

FFT analysis, real-time octave analysis (RTA) ※1, rotation tracking analysis ※2, as well as linear/Log sweep analysis using signal output and amplitude vibration control of electromagnetic vibration systems ※3 are all condensed into a portable unit.

Simultaneous recording during analysis is also possible, and offline analysis can be performed with the CF-9200A/CF-9400A main unit and surrounding software.

※1 An octave analysis function (CF-0923) is required.
※2 A tracking analysis function (CF-0922) is required.
※3 A Log sweep/vibration control function (CF-0942) is required.

Fanless & spindle-less for silent and vibration-free operation Silent

CF-9400A main unit installed in an anechoic chamber.

The CF-9200A/CF-9400A achieves high-performance operation without fans or spindles. It does not emit mechanical noise or vibrations from the main unit. In the field of acoustic and vibration measurement and recording, the CF-9200A/CF-9400A main unit does not become a source of noise or vibration.

By attaching a wireless LAN adapter, it is possible to operate the main unit using a tablet device, etc., without touching the CF-9200A/CF-9400A main unit ※.

Real-time Tripartite Graph / VC Curves (Vibration Criterion Curves)

real-time tripartite graph display function

The CF-9200A/CF-9400A can simultaneously read frequency (Hz) and three amplitude values (acceleration (m/s 2)/velocity (m/s)/displacement (m)) in real time using a tripartite graph ※1.
Additionally, by performing 1/3 octave processing and displaying the VC curve ※2 (Vibration Criterion Curves), it allows for a quick assessment of the allowable vibration standards and installation environment evaluation for vibration-sensitive precision instruments such as AFM, electron microscopes, and laser interferometers.

Unlike conventional methods that require separate differentiation and integration processing for frequency analysis to convert amplitude values, it enables speedy readings of each amplitude value.

※1 The tripartite graph (figure) allows for amplitude readings of acceleration (m/s 2), velocity (m/s), and displacement (m) based on the frequency (Hz) axis.

※2 The VC curve is proposed as a standard for allowable micro-vibrations when installing precision machinery. When using the VC curve, evaluation is conducted in 1/3 octave bandwidth, and the standards are divided into five levels (VC-A, VC-B, VC-C, VC-D, VC-E) in 6 dB increments, serving as guidelines for applications ranging from optical microscopes to long optical path laser devices.

Generic Vibration Criteria for Vibration-Sensitive Equipment, Colin G.Gordon, SPIE99Evolving criteria for research facilities: I-Vibration

Wide Dynamic Range

Wide Dynamic Range

The CF-9200A/CF-9400A features a newly developed front end with 24-bit A/D, achieving a wide dynamic range of over 120 dB. It eliminates the need for changing the voltage range due to A/D over, which was frequently done in normal acoustic and vibration measurements.

There is no longer a need to redo measurements or data records, significantly advancing measurement and analysis work, and allowing beginner users who are unfamiliar with FFT analyzers to use it with confidence.

Full Input Isolation

Full Input Isolation

The CF-9200A/CF-9400A isolates (insulates) all signal input channels.
It has high resistance to ground loops and noise superposition, achieving reliable measurements in measurement sites and targets where potential differences are likely to occur.

Additionally, it protects important systems from FFT signals and sensors that may be exposed to dangerous transient voltages.

CCLD ※ equipped TEDS ※ compatible

Each input channel is equipped with CCLD (Constant Current Line Drive) for sensor power supply. Built-in preamplifier accelerometers, charge output type accelerometer charge converters, and measurement microphones can be directly driven from CF-9200A/CF-9400A.
Additionally, using TEDS sensors allows for automatic power supply to the sensor and unit calibration.

※ CCLD (Constant Current Line Drive) refers to a constant current drive method for sensor interfaces. By supplying constant current power to built-in preamplifier type accelerometers and measurement microphone preamplifiers, they can be directly connected to inputs such as FFT analyzers without the need for external amplifiers. Typically, the constant current power supply is around 2 to 4 mA.

※ TEDS (Transducer Electronic Data Sheet) is a general term for a format that describes sensor-specific information embedded in measurement sensors, as specified in the IEEE1451 series. By directly connecting TEDS sensors that incorporate TEDS information, the information is automatically read, eliminating the need for cumbersome calibration work, thus reducing measurement preparation time and enabling reliable measurements.

Easy operation with gestures.

Zoom in with a swipe

The CF-9200A/CF-9400A features a 10.4-inch LCD with a capacitive touch panel.

Gesture operations such as tapping and swiping are adopted for FFT graph manipulation. It has become easy and intuitive to zoom in and out on the desired bandwidth or gain.

Graph scale fitting of waveform amplitude, waveform swapping, zooming in and out on the time axis and frequency axis, waveform offset, and span adjustment can all be done with smooth gesture operations.

Reliable operation with a large hard key.

large hard key

The CF-9200A/CF-9400A performs major operations, switching of display data types, and data saving through newly developed large hard key operations from power ON/OFF.

It provides quick and reliable operation even in unstable and narrow spaces, preventing data loss and malfunctions.

Additionally, it is equipped with a lock function (HOLD) for hard keys and touch panels, preventing unintended contact that could lead to malfunctions or setting changes.

Good visibility. LED indicator.

LED indicator

The CF-9200A/CF-9400A displays the main operating conditions of the FFT with LED indicators.

From the startup process to the charging status of the built-in secondary battery, and starting with the A/D converter's Over, major hard keys are also equipped with LEDs, allowing the operator to know the operating status of the FFT from a distance.

disconnection detection function

disconnection detection function

Automatically detects cable disconnection or connector failure of the accelerometer and microphone ※.

Prevents troubles before the actual measurement.
The CF-9200A/CF-9400A also allows disabling the disconnection detection function.

※ Built-in constant current drive (CCLD) type preamplifier.

MEMORY

SSD (built-in CF-9200A/CF-9400A models)

The internal SSD (Solid State Drive) of the CF-9200A/CF-9400A can record time-series waveforms digitized with 24-bit A/D while performing FFT analysis. Recorded data can also be analyzed offline using FFT. Additionally, various analysis results can be stored in the memory area.

SSD/SDHC/SDXC memory cards

Compatible with SD/SDHC/SDXC cards, supporting a maximum capacity of 128GB (SDXC). In addition to storing various FFT data, it is also possible to save record data (ORF).

USB memory

The CF-9200A/CF-9400A can use general-purpose USB memory. In addition to being able to save various FFT data to the USB memory, it is also possible to transfer FFT data and record data stored in the internal SSD of the device.

DATA SHARING

LAN connection shared folder feature standard feature

FFT measurement data and record data (ORF) saved on the built-in SSD mounted on CF-9200A/CF-9400A can be accessed directly from a Windows® PC ※.
Data extraction and graphing with dedicated software can be done comfortably.
Data saved on the CF-9200A/CF-9400A can be easily copied and saved to the PC.

Conditions for the connecting PC: Windows® 10 (32-bit version, 64-bit version)

LAN connection feature some options

LAN connection function

By connecting the CF-9200A/CF-9400A to a Windows® PC using a LAN cable, it is possible to copy and write various measurement data, and to operate from the PC side using the remote desktop function ※1, as well as project the screen of the CF-9200A/CF-9400A using a projector.

Additionally, by using the optional LAN external control function (CF-0947), the CF-9200A/CF-9400A can be controlled using a program.

Connection PC requirements: Windows® 10 (32-bit version, 64-bit version)

Wireless LAN connection feature Option

Wireless LAN connection function

By attaching a wireless LAN adapter ※2 to the CF-9200A/CF-9400A main unit, you can wirelessly transfer FFT data and record data saved on the CF main unit to a Windows® PC.

Additionally, by using the remote desktop function ※1, you can display the screen and perform remote operations of the CF-9200A/CF-9400A series on a Windows® PC or various portable information devices.

short-range wireless communication connection function

cf9200a-cf9400a-22png

By attaching the short-range wireless communication adapter ※2 to the CF-9200A/CF-9400A main unit, you can wirelessly output the graph on the display screen to a mobile printer ※3 with just the operation of the "PRINT" button on the main unit. You can also connect devices like keyboards wirelessly.

*1 Please use Microsoft® Remote Desktop
*2 Please use TP-Link Bluetooth® adapter.
*3 Please use recommended products.

FFT basic analysis function

time axis waveform

Time Axis Waveform Display Screen for CF-9200A/CF-9400A

The voltage signals from sensors such as vibrations, noise, distortion, and current probes are converted to A/D and displayed as data in the time axis domain.

With the search cursor, you can directly read the X-axis and Y-axis values of any point, and using the delta cursor function, you can easily read time differences and level differences.

By using the time axis statistical analysis function, quantitative analysis of time waveforms such as mean (MEAN), root mean square (RMS), and crest factor can be performed, as well as abnormal diagnosis.

power spectrum

Power spectrum display screen of CF-9200A/CF-9400A

The power spectrum is obtained by performing FFT analysis to determine the power of each frequency component contained in the captured time-domain waveform, based on the frequency band width (frequency resolution ⊿f), and is graphically represented with frequency on the horizontal axis.

By conducting power spectrum analysis, it is possible to measure vibration noise levels and detect equipment anomalies and natural frequencies of structures that are difficult to estimate with time waveforms alone.

frequency response function

frequency response function

The frequency response function (FRF) represents the ratio of input to output in mechanical or electrical circuits on the frequency axis in terms of gain characteristics and phase characteristics.

The gain characteristic indicates how the amplitude changes as the input signal passes through the transfer system being evaluated, with the Y-axis displayed as the amplitude ratio of output to input.

The phase characteristic shows the lead or lag of the phase between the input and output signals, with the Y-axis displayed in degrees or radians.

Option Analysis Software

Tracking Analysis Function (CF-0922)

Tracking Analysis Function (CF-0922)

The tracking analysis function (CF-0922) automatically saves vibrations and noise generated when various rotating machines operate in low to high-speed ranges while performing FFT, allowing for the analysis of physical phenomena such as vibrations and noise that change with speed based on the rotational speed.

Machines that rotate around an axis, such as engines, gearboxes, turbines, and electric motors, operate over a wide range of speeds from low to high. At specific rotational speeds, components may resonate, causing significant vibrations and noise. To reduce the risk of damage and improve the quietness of the equipment, it is necessary to evaluate the relationship between the rotational speed and the natural frequencies of the components.

By using the tracking analysis function (CF-0922), the relationship between rotational speed and the resulting physical phenomena can be visualized and analyzed from various perspectives, such as color maps, three-dimensional graphs, and harmonic components based on one rotation, allowing for an overview of the specified rotational speed range.

Octave Analysis Function (CF-0923)

Octave Analysis Function (CF-0923)

An octave means double the frequency, and because the frequency characteristics perceived by the ear are geometric, octave analysis (CF-0923) is effective for noise analysis.

In the frequency range of the noise to be measured, it is possible to obtain the sound pressure level for each band by passing through bandpass filters specified by the 1/1 octave or 1/3 octave standards.

Log Sweep / Vibration Control Function (CF-0942)

Log Sweep / Vibration Control Function (CF-0942)

The Log sweep function continuously varies the frequency of the driving sine wave from the 1ch signal output module (CF-0971), allowing for the evaluation of the resonance point of the target transmission system.

By performing a sine sweep on the frequency axis using a Log scale, it is possible to obtain gain and phase for each frequency, enabling the accurate determination of the response function with a high S/N ratio.

Additionally, the vibration control allows for the control of the amplitude of the vibrator within an arbitrary range during vibration and sweeping, enabling vibration tests to be conducted without considering the frequency characteristics of the electromagnetic vibrator.

Diagram of Log Sweep Vibration Control

* The use of the Log sweep/vibration control function (CF-0942) requires the 1ch signal output module (CF-0971).

System Configurations

  • Example of system configuration centered around CF-9400A/CF-9200A.

CF-9200A/CF-9400A × O-Solution

O-Solution allows you to import and browse data recorded and saved with the CF-9200A/CF-9400A.
It is a software series that enables smooth data editing, processing, and analysis.

  • CF-9200A/CF-9400A × O-Solution

Specifications

  • number of input channels CF-9200A: 2 channels / CF-9400A: 4 channels
    input format Single End
    Isolation Isolation of each channel (always)
    input connector BNC (CO2 type)
    input impedance 1 MΩ ±0.5 % 100 pF or less
    Input combination DC or AC (0.5 Hz - 3 dB ±10%)
    Constant Current Drive for Sensors (CCLD) Current supply to the constant current supply type sensor via input connector (BNC terminal):
    +23 V to 26 V / 4 mA ±25 % (25 ℃)
    disconnection detection function Detecting cable disconnection when using CCLD.
    TEDS * Note) IEEE1451.4 Template Ver.0.9/1.0 accelerometer, microphone,
    IEEE1451.4 Template Ver.1.0 force sensor
    Absolute Maximum Input Voltage AC 70 Vrms for 1 minute (50 Hz)
    Input Voltage Range 1 Vrms, 31.62 Vrms (2 ranges)
    DC offset Below -60 dB F.S (when auto-zero is ON)
    Input Level Monitor Red LED lights up due to excessive input (lights up at range F.S).
    Frequency Range DC to 100 kHz
    Analog to Digital Converter 24-bit Delta-Sigma type
    dynamic range Above 120 dB (at FFT frame lengths of more than 4096 points and frequencies above 1 kHz)
    Amplitude flatness Below 20 kHz: ±0.1 dB,
    Above 20 kHz: ±0.2 dB
    harmonic distortion Below 20 kHz: -80 dB
    Above 20 kHz: -75 dB
    Aliasing below -80 dB
    Full scale accuracy ±0.1 dB (at 1 kHz)
    Amplitude Linearity ±0.0015% (at full scale)
    Crosstalk Between Channels Below -100 dB (at 1 kHz)
    Channel gain accuracy Below 20 kHz: ±0.05 dB
    Above 20 kHz (within the same range): ±0.1 dB
    Interval Phase Accuracy Below 20 kHz: ±0.3°
    Above 20 kHz: ±0.7°
    Anti-alias filter 4th order Butterworth: LPF 450 kHz -3 dB
    digital filter FFT aliasing filter Baseband: 10th order ellipse
    Zoom: 6th order ellipse
    Real-time Octave Band Filter 6th order Butterworth IEC 61260-1:2014 Class 1
    JIS C 1513-1:2020 Class 1 (compliant in filter shape)
    acoustic filter Acoustic A and C characteristics IEC 61672-1:2013 Class 1
    ANSI S1.4-2014/Part1 Class 1
    JIS C 1509-1: 2017 Class 1 (compliant in filter shape)
    External sample input Input Connector BNC (C02 type)
    Input Voltage Range ±12 V
    input impedance 100 kΩ
    Input combination AC/DC
    detection level 12 V ~ 12 V step 0.025 V
    slope + (rising) or - (falling)
    hysteresis level Arbitrary setting (initial value 0.5 V, range 0.025 V to 24 V)
    Input frequency range 0 to 300 kHz (out-of-band filter 300 kHz -3 dB)
    Absolute Maximum Input Voltage AC/DC 30 V
    Input pulse count per rotation 0.5 to 1024 P/R
    Input Pulse Division Function Mandatory if the input frequency at step 1 exceeds 4 kHz for frequency division from R1 to 1024.
    waveform monitor Waveform can be confirmed on the screen.
    External Sample Input LED LED (EXT SAMP) lights up green during pulse detection.
    External trigger input Input Connector BNC (C02 type)
    Input Voltage Range ±12 V
    Input combination AC/DC
    detection level -12 V to 12 V step 0.025 V
    slope + (rising) or - (falling)
    hysteresis level Arbitrary setting (initial value 0.5 V, setting range: 0.025 V to 24 V)
    Input frequency range 0 to 300 kHz (out-of-band filter 300 kHz -3 dB)
    Absolute Maximum Input Voltage AC/DC 30 V
    waveform monitor Waveform can be confirmed on the screen.
    External Trigger Input LED

    LED (EXT TRIG) lights up green during pulse detection.

    * Note) When using third-party TEDS compatible sensors: Depending on the type of TEDS dedicated chip inside the sensor, it may not be possible to read TEDS information.
    1: If you are considering purchasing a third-party sensor, please consult with each TEDS compatible sensor manufacturer or retailer for operation confirmation.
    2: If you would like to use your TEDS compatible sensor with our TEDS compatible measuring instrument, please confirm operation with our demo products. (Please contact your nearest sales office.)

  • Size 10.4 inch type
    Resolution 800 × 600 dots
    method Equipped with a TFT color LCD and a capacitive touch panel.
    Brightness adjustment Bright/Dark 2 Levels
    Lighting (backlight) LED

    The TFT color LCD display is made using very advanced technology, but there may be pixels (dots) that are non-lit or always lit. The ratio of effective dots is over 99.999% for a resolution of 800x600 dots. Variations in color and brightness may be visible depending on the viewing angle or temperature changes, but these are not considered defects, so we cannot accept exchanges or returns. Thank you for your understanding.

  • power switch A long press of about 1 second turns the device power ON/OFF; if held while the power is ON, it will force the power OFF.
    soft key Detailed settings for each function can be configured using the soft keys below the LCD screen.
    Direct key Cursor & Selector Part Key Up, Down, Left, Right, SEARCH, ⊿SET, ESC
    Measurement Department Switch SCHED, TRIG ON, AVG, START, STOP, etc.
    Waveform Selection Section TIME, SPECT, PHASE, FRF, COH, C-SPECT, SELECT
    misoperation prevention function Long press to lock and unlock the soft keys and direct keys (excluding the power switch).
    Print Key When connecting the recommended printer, the screen display will be for direct printing.
    Auto Sequence Playback Key Play back the registered automatic sequence of operations.
    Frequency range switch key Frequency left and right
    Y-axis scale switch key Y SCALE up and down
    Signal Output ON/OFF SIGNAL OUT (Enabled when CF-0971 option is installed)
  • frequency range 100 mHz to 100 kHz
    frequency accuracy Reading value accuracy of ±0.005% (±50 ppm)
    sampling frequency Frequency of 2.56 times the analysis range (during internal sampling)
    Sampling points / Analysis points
    Number of sampling points analysis points
    256 100
    512 200
    1024 400
    2048 800
    4096 1600
    8192 3200
    16384 6400
    overlap processing MAX/66.7%/50%/0%/optional
    window function Rectangular / Hanning / Flat Top / Force / Exponential / User Defined
    delay function It is possible to delay the time frame of other channels by 0 to 8191 points based on CH1.
    Time waveform processing function 1st floor, 2nd floor differentiation / 1st order, 2nd order integration
    Absolute value transformation / DC cancellation / Trend removal / Smoothing
    FFT real-time rate 100 kHz/4CH (FFT frame length of 2048 points or less, internal sample time)
    averaging function Number of Averaging Settings 1 to 65535 times
    Average setting time 0.1 to 999 seconds, in increments of 0.1 seconds
    It is possible to stop the average based on either frequency or time.
    time domain Additive average / Index average
    frequency domain Addition Average / Exponential Average / Peak Hold / Subtraction Average Sweep Average / Fourier Average / Max Overall
    amplitude domain cumulative average
    A/D over-cancel / double hammer cancel function / averaging permission selection function (ADD +1) / averaging undo function
    trigger function LED (TRIG'D) blinks green when triggered.
    Trigger Level -99 to 99 (unit: %) Default = 25 %
    Threshold setting is possible based on amplitude units (including user calibration values)
    hysteresis level 0 to 99 (unit: %) Default = 2%
    position ±16383
    mode Free / Repeat / Single / One Shot
    source CH1/CH2 (CF-9200A) ~ CH3/CH4 (CF-9400A) / External Trigger Input
    slope +/−/± (internal trigger) +/− (external trigger)
    FFT calculation 32-bit floating-point (IEEE single precision format)
  • time domain Time axis waveform / Autocorrelation function / Cross-correlation function / Impulse response / Cepstrum
    amplitude domain Amplitude Probability Density Function / Amplitude Probability Distribution Function
    frequency domain Power Spectrum / Fourier Spectrum / Lifted Spectrum / Cross Spectrum
    Computational function (time axis statistical processing) Mean / Absolute Mean / Effective Value / Standard Deviation / Maximum Value / Minimum Value
    Wave Height Ratio (Crest Factor) / Skewness / Kurtosis
  • recording device Internal storage of the device or SD/SDHC memory card can be selected.
    Recording function
    frequency range 100 kHz (max)
    Recording channel CH1/CH2 (CF-9200A) CH1 to CH4 (CF-9400A),
    rotation information recording is also possible
    recording time 4 GB: Approximately 32 minutes, 50 kHz range, 4-channel recording, rotation information OFF, 2048 sample points.
    Record format ORF
    Maximum recording capacity SD / SDHC / SDXC (maximum SDXC 128 GB)
    data file 9990 (999 data × 10 blocks) data
    DAT/TXT/BMP (can record analysis data in three formats simultaneously (TXT, BMP can be selected))
    file format It is possible to record analysis data in three different formats simultaneously (TXT and BMP are selectable)
    DAT/TXT/BMP (when saving as TXT, list data can also be saved)
    Panel Condition Memory Store and recall measurement conditions (up to 50 types).
    handwritten note Memorize handwritten notes written on the touch panel.
  • USB number of ports 3 (USB 3.0 × 2, USB 2.0 × 1)
    USB (Type A) For USB memory (USB 3.0 and USB 2.0), wireless LAN module, and Bluetooth ® adapter
    wireless connection wireless LAN module Recommended product by TP-Link.
    Bluetooth ® adapter Recommended product by TP-Link.
    SD card slot number of slots 1
    Compatible with SD / SDHC / SDXC Capacity: Maximum SDXC 128 GB
    (Does not guarantee operation of all SD / SDHC / SDXC cards)
    LAN number of ports 1
    10BASE/100BASE-TX/1000BASE-T Remote Desktop, External Control
    printer output Print using the main unit's PRINT key.
    Interface USB or Bluetooth ® (when using TP-Link Bluetooth ® adapter)
    compatible printer MW-270 manufactured by Brother Industries, Ltd.
    output data Screen copy / List display copy
  • Condition View Display of the list of setting conditions.
    clock Year, Month, Day, Hour, Minute, Second
    Operation confirmation sound / Warning sound Can be turned ON/OFF at will.
  • Power Supply included AC adapter or included battery
    Power consumption CF-9400A
    (when equipped with CF-0971 signal strength option)
    Below 87 VA (when using an AC adapter, when the battery is not charging)
    150 VA or less (when using AC adapter, during battery charging)
    CF-9200A
    (when equipped with CF-0971 signal output option)
    73 VA or less (using AC adapter, when the battery is not charging)
    150 VA or less (when using AC adapter, during battery charging)
    Operating temperature range 0 to +40 °C (humidity 20 to 80 %RH, with no condensation)
    Storage Temperature Range -10 to +50 °C (including lithium-ion secondary batteries) (Humidity 20 to 80 %RH, without condensation)
    functional grounding terminal ground terminal for noise removal
    Outline Dimensions Less than 333 (W) × 248 (H) × 112 (D) mm *excluding protruding parts such as handles and stands.

    CF-9200A External Dimension Drawing

    Main body cooling natural air cooling (fanless)
    Weight Approximately 3.8 kg when the battery is not installed.
    Approximately 4.8 kg when two batteries are attached.
    CE marking Low Voltage (LVD) Directive 2014 / 35 / EU Standard EN61010-1
    EMC Directive 2014 / 30 / EU Standard EN61326-1
    RoHS Directive 2011 / 65 / EU Standard EN IEC 63000
    Accessories AC adapter (power cable for AC adapter (2 m)) Quantity 1
    Battery (RRC2020 (100496-15) lithium-ion secondary battery) Quantity 2
    User Manual (CF-9200A/CF-9400A User's Guide Book) Quantity 1
    CD-ROM (reference guide, utility, DLLs for external control, etc.) Quantity 1
    SD card (4 GB) Quantity 1
  • input voltage AC 100 to 240 V
    Input frequency 50/60 Hz
    output voltage fixed at 16 V
    output current Freeze 4 A
    safety standards PSE/CE/UL/GS
  • Battery lithium-ion secondary battery
    Built-in (hot-swappable) in the main unit.
    quantity Can attach 2 pieces
    driving time Continuous 8 hours operation (with 2 new batteries installed)
    4CH 100 kHz analysis / Signal output OFF / LCD backlight (bright) /
    USB port not in use
    Battery status display main screen When a secondary battery is installed, the remaining capacity is displayed on the main screen.
    Battery LED (BATT1, BATT2) During charging, orange light is on, and when fully charged, green light is on
    (when AC adapter is connected)
    LOW BATT red light on (lights up at 5% or below)
    (when running on battery without AC adapter)
    Display a low battery warning message when the battery level is below 15%.
    Processing at the minimum remaining level. Display a low battery warning message and perform auto shutdown when battery level is below 3%.
    Remember the previous panel condition.
    charging time When the main unit is operating About 7 to 8 hours (depending on usage conditions)
    when the power is off approximately 7 to 8 hours
    External charger (recommended item) approximately 4.5 to 5 hours
  • Number of Channels 1
    Output terminal shape BNC (C02 type)
    Isolation non-insulated
    output voltage amplitude ±1 mV to ±10 V (amplitude + DC offset)
    output format Unbalanced output
    Output coupling DC
    protection circuit short circuit protection
    output impedance 0 Ω or 50 Ω ±10%
    maximum output current 10 mA
    offset voltage ±10 V
    Digital to Analog Converter 16 bit
    conversion rate maximum 512 kHz
    Digital to Analog Converter 16 bit
    output waveform Sine wave / Swept sine / Pseudo-random / Random / Impulse
    THD and spurious -75 dB or lower (sine wave at 1 kHz, output amplitude ±1 V)
    Adaptive FFT analysis length 256~16384
    zoom analysis Correspondence (linked to the zoom analysis range)
    Voltage amplitude accuracy Within ±0.5 dB (at 1 kHz, 1 V0-p, with a 1 MΩ load)
    frequency accuracy ±50 ppm
    digital filter smoothing filter When a secondary battery is installed, the remaining capacity is displayed on the main screen.
    At zoom: 6th order ellipse
    octave band filter 1/1 or 1/3 octave
    6th Butterworth
    pink filter Analog method -3 dB/oct ±1.0 dB (specified from 20 Hz to 20 kHz)
    burst function Single burst, continuous burst
    Burst Cycle sine wave 1 to 32767 cycles
    Swept Sign / Pseudo-Random / Impulse 1 to 32767 FFT frames
    random 1 ms to 32 s
    Cycle setting unit
    and burst interval
    sine wave one cycle of a sine wave
    Swept Sign / Pseudo-Random / Impulse 1 FFT frame
    random 1 ms
    taper function The output can gradually increase or decrease during the ON/OFF signal.
    1 ms to 32 s (in increments of 1 ms)
    However, the function is disabled when the burst function is ON.
    spectral flatness 20 kHz to 100 kHz: within ±1.0 dB
    0 to 20 kHz: within ±0.2 dB
    Crest Factor sine wave approximately 1.41
    Swept Sign Approximately 1.4 to 1.6
    pseudo-random 3.3 or below
    random 3.3 or below
    impulse below 32.0

Optional Software Specifications

  • Measurement Mode (FRA Mode)
    Measurement Frequency Range 10 mHz to 100 kHz
    Frequency Resolution (Log Sweep) 10, 20, 40, 50, 80, 100, 120, 160, 200, 250, 300, 320, 400, 500 books per decade
    Frequency Resolution (Linear Sweep) 100, 200, 400, 500, 800, 1000, 2000, 2500, 4000, 5000 pieces / full bandwidth
    average count 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 20, 25, 30, 40, 50, 60, 80, 100, 120, 150, 180, 200 times and any number of times.
    Frequency Range Division Setting Mode The measurement frequency range can be divided into a maximum of 10 segments, allowing for changes in the number of additions and the signal output level for measurement.
    Auto Resolution Control Function A feature that automatically optimizes the decades of each frequency band to enable accurate observation of characteristics across the entire frequency range.
    function for expanding frequency resolution It is possible to generate a sine wave with a frequency resolution that is 20 times finer than the frequency range resolution during measurement, enabling re-measurement.
    computational function Frequency axis calculus functions (1st derivative, 2nd derivative, single integral, double integral)
    Arithmetic operation functions
    Display
    Display of frequency response function Bode plot (horizontal axis: frequency / vertical axis: gain and phase)
    Display of frequency response function Nyquist diagram (horizontal axis: real part / vertical axis: imaginary part) allows for logarithmic scale representation of amplitude.
    display mode

    FRF mode (3-screen display)
    1) FRF (board diagram), COH (can toggle display ON, OFF)
    2) Either Nyquist or SPEC (1, 2ch overlay)
    3) TIME, instantaneous spectrum (can display overlaid and specify channels)

    List mode 1 screen display
    1) Measurement conditions
    2) All measurement data No./Frequency/FRF gain/FRF phase/COH/FRF real part/FRF imaginary part/SPEC1/SPEC2/List of number of additions
    Peak List mode 2 or 3 screen display
    In the FRF board diagram display, frequency, gain, and phase are listed in two ways
    1. Peak points of gain (automatic search)
    2. Arbitrary points
    Memory mode
    1) Current state FRF
    2) List of stored waveforms
    3) Overlay display of the waveform selected in 2) (up to 20 screens)
    Calculation screen (4 screen display)
    1) Current FRF
    2) Stored FRF
    3) Waveform of the results of arithmetic operations and calculus operations on 1) and 2), waveform of the results of open/closed loop conversion from 1) and 2) *Calculation result waveform can also be displayed
    4) Nyquist diagram of the calculation results from 3)
    display function Phase Unwrap Representation
    Search Delta Function
  • Types of tracking analysis phase tracking
    Amplitude Tracking
    sampling method Constant ratio tracking (external sample): up to the maximum number of analysis times.
    Fixed-width tracking (internal sample): the frequency range is the same as that of FFT analysis.
    Number of FFT sampling points. Power Spectrum Index Average
    Fourier Spectrum Exponential Average
    maximum number of analyses 800 times (6.25, 12.5, 25, 50, 100, 200, 400, 800)
    maximum block count 1000(100、200、400、800、1000)
    Analysis screen display 6 screens / tracking display with list view available
    display function Time axis waveform, frequency analysis (amplitude, phase), order ratio analysis (amplitude, phase),
    constant ratio tracking analysis (amplitude, phase), constant width tracking analysis (amplitude, phase),
    fixed frequency tracking analysis (amplitude, phase), time tracking analysis (amplitude, phase),
    three-dimensional map, Campbell diagram
    Number of displayed tracking diagrams 8 books (MAX order, O.A separate)
    schedule function Rotation schedule (with automatic descent detection function)
    Time Schedule (Time Trend)
    Setting of upper and lower limits for rotation speed UP (lower limit to upper limit)
    DOWN (upper limit to lower limit)
    UP/DOWN (lower limit → upper limit → lower limit)
    DOWN/UP (Upper limit → Lower limit → Upper limit)
    Simultaneous recording function for analysis Only supports fixed-width tracking.
  • types of octaves 1/1 octave and
    1/3 octave (filter: 6th order Butterworth)
    JIS C 1514:2002 Class 1, IEC 61260 Ed.1.0 (1995) Class 1 ANSI
    Compliant with ANSI S1.11:2004 Class 1
    Time weight (time constant) 10 ms、35 ms、125 ms(FAST)
    630 ms, 1 s (SLOW), 8 s,
    IMPULSE rise time 35 ms / fall time 1.5 s
    Compliant with JIS C 1509-1:2005 Class 1 and IEC 61672-1:2002 Class 1.
    Analysis Frequency Range 0.8 to 20 kHz (1/3 octave)
    1 to 16 kHz (1/1 octave)
    computational function Instantaneous value, maximum value per second, maximum value hold, minimum value hold
    Average power value, total power value, linear Leq
    Analysis screen display Up to 6 screens (with data overlay available)
    Real-time octave display with list function available.
    Simultaneous recording function for analysis response
    Option CF-0922 (tracking analysis function)
  • Client PC (OS) Microsoft® Windows® 11 Pro (64-bit version),
    Microsoft® Windows® 11 Enterprise LTSC (64-bit version) *,
    Microsoft® Windows® 10 Pro (64-bit version)
    Software Microsoft® Visual Studio 2019 (VB, C#)
    Microsoft® Office Excel 2016
    .NET Microsoft® .NET Framework 4
    network cable LAN cable ** Category 6
    • Windows® 11, Windows® 10, Microsoft® Visual Studio, and Microsoft® Excel are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries.
    • Windows 11 Enterprise* has been tested to operate in a Windows environment with standard settings (under standard policy settings).
      Operation in environments where security settings, group policy changes, or the introduction of third-party security software have altered the standard settings is not guaranteed. Therefore, support may be limited.
    • LAN Cable: Depending on the device you are using, a straight cable connection may not be possible. If you are using a straight cable, please confirm that your device supports Auto MDI/MDI-X.

Options

Model name Product Name
CF-0922 Tracking Analysis (Software Option)
CF-0923 RTA analysis (software option)
CF-0942 Log sweep / vibration control (software option) *CF-0971 is required.
CF-0947 LAN external control function (software option)
CF-0971 1CH Signal Output Module (installation cost not included)
CF-0951A Reference Guide (Japanese version) booklet edition (PDF version included on the attached CD-ROM)
CF-0951AE Reference Guide (English version) printed edition (PDF version included on the attached CD-ROM) August 2014 onwards
CC-0025A soft carrying case
CC-0091 hard carrying case
RRC2020 *1
(100496-15)
Batteries (2 included at the time of purchase)
PS-P20025A Battery charger set (includes charger and AC adapter. A separate AC power cable is required.)
  security software

*1: The RRC2020 (100496-15) battery is for CF-9200A/CF-9400A. It cannot be used with CF-9200/CF-9400.

recommended products

Model name Product Name / Manufacturer
UB400 Bluetooth ® adapter made by TP-Link
TL-WN725N Wireless LAN module, manufactured by TP-Link.