Skip to content

Select your region & language

Global

Region

Notice of a problem when performing octave analysis with the XN-8000 series and setting time weighting to Impulse

Thank you for your continued patronage of our products.
We have discovered a problem with the octave analysis function of the XN-8000 series that you recently purchased, specifically when the time weight is set to Impulse. We sincerely apologize for causing this issue and promise to prevent such a problem from recurring.
We sincerely apologize for any inconvenience this may cause to our customers using this product. We kindly request that you install the latest version of the software with the fix implemented. Please refer to "■ How to Upgrade" at the bottom of this page for instructions.
We sincerely apologize for bothering you during this busy time, but we would appreciate your understanding and cooperation.
If you have any questions or concerns, please contact our customer service department listed below.

Causes and symptoms of the malfunction

When performing an analysis with the time weight set to Impulse, there was a bug in the processing of the remaining levels when switching from a falling time constant of 1500ms to a rising time constant of 35ms.
When time weighting is set to Impulse during octave analysis, the values for each band and the Allpass may become larger than the correct values.

Target Products

Model name Software Version
XN-0823 Real-time Octave Analysis Prior to Ver 2.5.1.2

countermeasure

We have prepared a version that fixes the above bug.
Please download the latest updated software and perform an overwrite installation on the computer where your XN-8000 is installed.

Previous version Revised version
Prior to Ver 2.5.1.2 → 2.5.1.2

How to upgrade (Scheduled for release on February 6th)

Clicking the "Go to User Login/Registration Page" button below will take you to the "User Registration & Download" page.
"Repolyzer Measurement Processing Software" on the displayed page

  • How to upgrade (Scheduled for release on February 6th)

First-time users should click [New Registration], and existing users should click [Special User Page Login] to proceed to the XN-8000 software download page, from which you can download the installer.

We apologize for the inconvenience caused by the login and registration processes.
Please fill in the information.

* The XN-8000 bug fix software will be available for download from February 6th onwards.

The information on this page is based on the information available at the time of publication.
Please note that if product sales are discontinued, organizational changes are made, or specifications are changed after publication, the information may differ from the latest information.