Signal cables and accessories for digital linear gauges
Signal cable
Signal extension cable (sensor ↔ counter)
| Model name | length | Source | Exterior | Connection destination | price | |
| Signal extension cable |
AA-8801 | 5 m | BS/GS Series Linear gauge sensor |
The maximum extension cable length from the sensor is 30 meters. |
DG Series Gauge counter |
|
| AA-8802 | 10 m | |||||
| AA-8803 | 20 m | |||||
| AA-8804 | 30 m | |||||
Flexible signal extension cable * New |
AA-8811 | 5 m | BS/GS Series Linear gauge sensor |
The maximum extension cable length from the sensor is 30 meters. |
DG Series Gauge counter |
|
| AA-8812 | 10 m | |||||
| AA-8813 | 20 m | |||||
| AA-8814 | 30 m | |||||
| Signal extension cable |
AA-8901 | 5 m | GS-3813B GS-3830B Linear gauge sensor |
|
DG-5100 | |
| AA-8902 | 10 m | |||||
| AA-8903 | 20 m | |||||
| AA-8904 | 30 m |
Connection conversion cable (sensor ↔ counter)
| Model name | length | Source | Exterior | Connection destination | price | |
| Connection Converter cable |
AA-8910 | 0.2 m | BS/GS Series Linear gauge sensor (GS-3800B) (Excluding the series) |
![]()
|
DG-5100 |
Signal cable (for output signal conversion box)
| Model name | length | Source | Exterior | Connection destination | price | |
| Signal cable |
MX-7105 | 5 m | DG-0010 Output signal Conversion box |
![]() |
Open collector output |
|
| MX-7110 | 10 m | |||||
| MX-7115 | 15 m | |||||
| MX-7120 | 20 m | |||||
| Made to order | 25~30 m | 25m: ¥22,000 (excluding tax) 30m: ¥27,500 (excluding tax) |
||||
| Made to order | 30~1200 m | DG-0020 Output signal Conversion box |
|
Line Driver output |
¥19,000 (excluding tax) ~ every 5 m extension ¥3,000 (excluding tax) |
BCD cable
| Model name | length | Source | Exterior | Connection destination | price | |
| BCD cable |
AA-8101 | 3 m | DG-4320/4340/ Gauge counter |
|
DA-4130 DA converter*** |
|
| AA-8107 | 3 m | DG-2310 4320/4340 Gauge counter |
![]()
|
- |
Power cable
| Model name | length | Source | Exterior | Connection destination | price | |
| Power supply cable |
AX-2050N | 3 m | DG-4320/4340/ 5100 Gauge counter |
![]()
|
- |
RS-232C cable
| Model name | length | Source | Exterior | Connection destination | price | |
| RS-232C cable |
AX-5022B | 2 m | DG-2310 Gauge counter |
![]()
|
PC |
* Do not store or use at temperatures below 0°C. (This differs from the sensor's storage temperature.)
** The DX30A-36P is a crimp-type connector. If you are wiring it yourself, you will need tools for crimp-type connectors. When purchasing connectors, we recommend solder-type connectors.
*** Sales ended
Mechanical release
Mechanical release
| Model name | Compatible gauge | Outline Drawings | Amount |
| AA-813 | GS-201*、GS-102* BS-102*/102W*/112*/112W*HS-3412*/3425* DG-525H*/825*/925* |
|
* To be used in combination with the AA-972 release lifter.
Finger lift
Finger lift
| Model name | Compatible gauge | Amount | |
| AA-969 | All models (BS series, (Excluding waterproof models) |
|
Air Lifter
Air Lifter
| Model name | Compatible gauge | Amount | |
| AA-6102 *2*3 |
GS- 1713/1813/ 6713/6813/ 4713/4813/ 3813 |
|
|
| AA-6103 *2*3 |
GS- 1730/1830/ 6730/6830/ 4730/4830 /3830 |
|
*1 Air Lifter is not covered by protection class IP64 or IP64G (AA-6100/6101)
*2 Because the Air Lifter AA-6102/6103 requires an extension spindle, the overall length of the gauge sensor will be 22 mm / 37 mm longer, respectively.
*3 Air piping and an ON/OFF solenoid valve are required separately. The distance from the sensor mounting surface to the spindle sensor (9 mm) remains unchanged.
Extension spindle
Extension spindle (for measuring the depth of deep small holes)
| Model name | Extension length | Amount | |
| AA-844 | 30 mm |
|
|
| AA-845 | 50 mm |
|
Measurement tip
Measurement tip
| AA-0200 *1 | AA-0210 | AA-0220 *2 | AA-0230 |
![]() |
![]() |
![]() |
![]() |
| AA-0240 *2 | AA-0250 *2 | AA-827 *3 | AA-828 *3 |
![]() |
![]() |
![]() |
![]() |
| AA-0320 | AA-921 | AA-0330 (Made to order) | AA-0400 |
![]() |
![]() |
![]() |
![]() |
*1 The BS series uses a measuring probe other than the standard measuring probe (AA-0200).
*2 When attaching the AA-0220/0240/0250 flat probe to a gauge with 1 μm or 10 μm increments, we recommend adjusting the parallelism with the surface of the measuring stand. In this case, it will be paired with a gauge stand. Accuracy after parallelism adjustment: Approximately 10 μm or less (according to our measurement method). Parallelism adjustment fee: ¥15,000 (excluding tax) (shipping fee is separate).
*3 When roller measuring probes such as AA-827/828 are attached to gauges with a precision of 1/1000 mm (1 μm), the specified accuracy may not be achieved. Although AA-827/828 uses bearings, the gap is not removed, so there is a possibility of an error of about ±10 μm.
Fittings and measurement tip adapters (for replacing tips)
Fittings and measurement tip adapters (for replacing tips)
| Model name | Compatible gauge | price | |
| AA-829 (Made to order) | GS-102/251/ 503/1000 (All models are no longer available for sale) |
![]() |
Dustproof rubber
Dustproof rubber
| Model name | Compatible gauge | L1 (mm) |
Collar outer diameter (⌀ mm) |
Rubber outer diameter (⌀ mm) |
Stem diameter (⌀ mm) |
Material *3 | price |
| AA-841 *1 | GS-1000 (Sales ended) |
40.5 | 22 | 24 | 15 | CR | |
| AA-973 *1 | BS-1210/1310/ 102/102W/ 112/112W |
- | - | 8 | 8 | EPM | |
| AA-975 *2 | GS-5011 | 8.5 | - | 16 | 20 | NBR | |
| Made to order | GS-4513/4613/ 4530/4630 *4 (All models are no longer available for sale) |
- | - | 10 | 10 | FKM | Product pickup/exchange *6 |
| AA-4102 | GS-1713/1813/ 6713/6613 |
- | - | 8 | 15 | Si | |
| AA-4103 | GS-1730/1830/ 6730/6830 |
- | - | 8 | 15 | Si | |
| AA-4104 | GS-4713/4813/ 3813 *5 |
- | - | 8 | 15 | HNBR | 商品引き取り交換*7 |
| AA-4105 | GS-4730/4830/ 3830 *5 |
- | - | 8 | 15 | HNBR | 商品引き取り交換*7 |
*1 Includes a dedicated measuring probe for dustproof rubber. (See the diagram below for the external dimensions.)
*2 Includes a dedicated fitting for dustproof rubber. (See the diagrams above and below for the external dimensions.)
*3 CR: Chloroprene rubber, NBR: Nitrile rubber, EPM: Ethylene propylene rubber, Si: Silicone rubber, FKM: Fluorine rubber, HNBR: Hydrogenated nitrile rubber
*4 Dustproof rubber (material: fluororubber) for GS-4500/4600 series is made to order. In that case, the product will be picked up and replaced.
*5 Dustproof rubber for GS-4700/4800/3800 series is replaced by product pickup.
*6 Shipping fees will be charged separately.
*7 Installation fees are separate.
| Model name | Compatible gauges / Product details | |
| AA-841 | Includes a dedicated measuring probe for dustproof rubber. For GS-1000* |
![]() |
| AA-973 | Includes a dedicated measuring probe for dustproof rubber. For BS series |
|
| AA-829 | Measuring probe adapter For GS-102*/251*/503*/1000* When using the dustproof rubber attachment and combining it with a special measuring probe, the measuring probe adapter AA-829 is required. |
![]() |
| AA-975 | Includes a dedicated fitting for dustproof rubber. For GS-5011* When using with a special measuring probe, attach it directly to the AA-975 (dedicated fitting for dustproof rubber). A separate fitting for the special measuring probe is not required. |
![]() |
Mounting bracket
Mounting bracket
| Model name | Compatible gauge | price | |
| AA-8560 | GS-5050/5051/5100/5101 |
|
|
| AA-3310 | GS- 1713/1730/ 1813/1830/ 3813/3830/ 4713/4730/ 4813/4830/ 6713/6730/ 6813/6830 |
|
Gauge stand
Gauge stand
| Gauge stand model name | ST-022 | ST-0230 *1 | ST-044B *1 | |
| Applicable gauge | Gauge sensor model name | BS-1210 BS-1310 |
GS-1713A/1730A GS-1813A/1830A GS-3813B/3830B GS-4713A/4730A GS-4813A/4830A GS-6713A/6730A GS-6813A/6830A |
GS-5050A/5100A GS-5051A/5101A |
| Reference | Stem outer diameter ⌀8 mm Stroke 10 mm |
Stem outer diameter ⌀15 mm Stroke 13/30 mm |
Stem outer diameter ⌀15 mm Stroke 50/100 mm |
|
| Table dimensions (mm) | 80 × 85 | 80 × 85 | 105 ×105 | |
| Applicable stem outer diameter (mm) | ⌀8 to ⌀10 | ⌀15 | ⌀15 to ⌀20 | |
| Table material | Ceramic (grooved) | |||
| Measurement surface flatness | 1μm | |||
| Surface roughness of the measurement surface | 0.4S wrap finish | |||
| Base (width x depth mm) | 100 ×160 | 130 × 200 | ||
| Measurable depth (mm) | 約 59 | 約 60 | 約 73.5 | |
| Measurable height (mm) | 約 115 | 約 210 | ||
| Weight | 4.1 kg | 4.2 kg | 7.5 kg | |
| price | ||||
*1 When using a linear gauge sensor with a stem outer diameter of ⌀8 mm mounted on a gauge stand ST-0230 or ST-044B, a stand bushing AA-891 (for ⌀8 mm) or AA-892 (for ⌀10 mm) is required.

Reference
To attach or remove the gauge sensor, use knob (A). To raise or lower the arm, loosen knob (B) first, then adjust it with knob (C).
Spare parts, consumables, etc.
Spare parts, consumables, etc.
| Model name | Product name | Purpose | price |
| DX40-36P | 36-pin connector (for cables) For BCD signals, for soldering (DX36CV1 required) |
For DG4120*/4140*/4240*/4280*, DA-4130 | |
| DX36CV1 | Plug cover for the same purpose | For DX40-36P | |
| TA2096 | AC power adapter (cable: approx. 1.8 m) Input: AC 100 V, Output: DC 9 V/300 mA |
For DG-525H*/825*/925* | |
| AA-5100 | Thermal recording paper (10 rolls per set) | For RQ-1410* |
* Sales ended
最終更新日:2024/12/13