Skip to content

Select your region & language

Global

Region

Rental of anechoic chambers, semi-anechoic chambers, and reverberation chambers.

  • We have an anechoic chamber with top-level performance in Japan.

  • Our audio and vibration specialists will assist you.

  • In addition to renting out our acoustic laboratory, we also offer equipment rentals and commissioned measurement services by our expert staff, according to your needs.

Service Introduction

anechoic chamber

  • anechoic chamber
Application example

Measurement of characteristics of microphones/speakers, etc.
Recording of dry source sounds, sound source detection using the SI method, etc.

Effective dimensions

7.0 (W) × 7.4 (D) × 6.5* (H) m (* Distance between sound-absorbing materials)
Height from piano wire floor to ceiling sound-absorbing material: 4.7 m

Indoor ambient noise

NC-15 or lower (A-weighted sound pressure level: 0dB or less)

Inverse Square Law

31.5 Hz to 10 kHz (1/3 octave band): 4 m
*JIS Z 8732(2000) Annex Table A.1

sound-absorbing layer

1.7 m wedge-shaped

semi-anechoic chamber

  • semi-anechoic chamber
Application example

Various noise level measurements
Measurement of sound power levels in office equipment and PC-related devices

Effective dimensions

8.2 (W) × 7.9 (D) × 5.4 (H) m

Indoor ambient noise

NC-15 or less (A-weighted sound pressure level: 5 dB or less)

Inverse Square Law

100 Hz to 10 kHz (1/3 octave band): 4 m
*JIS Z 8732(2000) Annex Table A.1

sound-absorbing layer

400 mm flat plate + air layer

Reverberation chamber

  • Reverberation chamber
Application example

Reverberation chamber method for measuring acoustic power level
Reverberation chamber method sound absorption coefficient measurement, sound transmission loss measurement, etc.

Effective dimensions

Sound source room: 6.5 (W) × 8.3 (D) × 5.3 (H) m
Sound receiving room: 6.7 (W) × 8.4 (D) × 5.4 (H) m

Reverberation time

125Hz: 11.7 seconds
500Hz: 9.7 seconds
2 kHz: 6.1 seconds

Rental fee

¥180,000 (excluding tax) / 1 day ¥90,000 (excluding tax) / half day (Applicable to anechoic chamber, semi-anechoic chamber, and reverberation chamber)
Additional charges apply for the use of equipment. For details, please contact your local sales office or customer service center.

Sound building configuration

  • Location: 1-16-1 Hakusan, Midori-ku, Yokohama City, Kanagawa Prefecture (Inside Ono Sokki Yokohama Technical Center Co., Ltd.)
    Location: 1-16-1 Hakusan, Midori-ku, Yokohama City, Kanagawa Prefecture (Inside Ono Sokki Yokohama Technical Center Co., Ltd.)