| Measurement target |
Conductors, semiconductors, insulators *1 *1 The CL-0300 insulation measurement function option is required. |
| Sensor input |
2-channel (A, B) capacitive sensor |
| Measurement items |
-
Thickness of the object being measured (conductor, semiconductor, insulator<option CL-0300>)
-
The gap (A) between sensor A and the object being measured (conductor, semiconductor)
-
Gap (B) between sensor B and the object being measured (conductor, semiconductor)
-
The difference between A and B (A - B)
|
| Display mode |
-
ABS: Thickness or gap expressed as an absolute value.
-
Dev: Display of the amount of change relative to the baseline value.
-
Maximum value (MAX), minimum value (MIN), and maximum value minus minimum value (RANGE) within a specified period (during START).
|
| Compatible sensors and display resolution |
When combined with the new VE series capacitive gap detector, the following display resolutions are achieved:
| Sensor type |
Measurement range (μm) |
Resolution (μm) |
| standard |
CL-0200 high resolution calculation function When options are installed |
| VE-2011 |
20~200 |
0.1 |
0.02 |
| VE-5010 |
50~500 20~200*1 |
0.1 |
0.05/0.02*1 |
| VE-5011 |
| VE-1020 |
100~1000 |
0.1 |
0.1 |
| VE-1021 |
| VE-1520 |
150~1500 |
0.5 |
0.2 |
| VE-3020 |
300~3000 |
1 |
0.5 |
| VE-8020 |
800 to 8000 |
2 |
1 |
| VE-8021 |
*1: The VE-5010/5011 can have its measurement range set to 20-200 μm using the CL-0201 measurement range change option. When the high-resolution option is installed in this case, the display resolution will be 0.02 μm. *When measuring insulators, please use approximately 1/3 of the measurement range as a guideline for thickness. For example, when using VE-1020, the thickness of the insulator will be approximately 350 μm or less.
|
| accuracy |
±0.15%/FS(Standard) ±0.12 %/FS (When the CL-0200 high-resolution calculation function option is installed <excluding VE-8020/8021>) |
| Accuracy guaranteed temperature range |
23℃ ± 2℃ |
| Display section |
Fluorescent display tube The display of measurement results can be switched between one item (uppercase) and two items (lowercase). |
| Parameter settings |
Various parameters necessary for measurement and calculation are set in the internal memory using the keys on the control panel. These settings are retained even when the power is turned off by the power-off memory. |
| Sampling time |
20 ms |
| Average |
Moving average: 1 to 64 times |
| Interface |
RS-232C: Enables remote control of this device and acquisition of measurement data. Printable on the DPU-414 printer (sold separately). |
BCD output function (Option: CL-0120) |
Output measurement results in 6-digit parallel BCD format. Output method: Open collector output Output data: Select from GAP-A, GAP-B, THICK, AB, DISP2 display values. Data update time: 20 ms Connection cable: AA-8207 (3 m, open on one end) |
| Remote function |
External operations such as starting/stopping calculation functions and thickness calibration are possible.
Remote terminal pinout and input signal
| A |
power supply |
Input DC 5-24V
- If supplying more than 6V DC from an external source, insert a resistor.
|
| B |
START |
Same function as the START key |
| C |
STOP |
Stop the calculation mode. |
| D |
PAUSE |
Same function as the PAUSE key |
| E |
CALIB |
Calibration using registered reference sample data for the object being measured.
- This is only valid when measuring conductors.
- The thickness of the reference piece for the object being measured cannot be changed.
|
| F |
START STATUS |
It is activated when in calculation mode and calculation interruption mode. |
| G |
+5V output |
Outputs +5 V (MAX: 0.3 A) |
| H |
COMMON |
Connect 0V
|
*Compatible connector: R03-PB8M (manufactured by Tajimi Musen)
|
| SYNC function |
Multiple CL-5610/CL-5610S units can be operated in parallel and synchronously (up to 2 units per master unit)*1 |
| Power supply |
AC 100V-240V 50/60 Hz |
| Operating environment (main unit only) |
Temperature: +23°C ± 2°C (guaranteed accuracy range), 0°C to +40°C (operating range) Humidity: 20-80% RH (but no condensation) |
| Outline drawings |
210 (W) x 99 (H) x 275 (D) mm (CL-5610/CL-5610S main unit, excluding protrusions)

56 (W) x 42.4 (H) x 122 (D) mm (for CL-5610S converter CL-0420, excluding protrusions)

|
| Weight |
Approximately 4.2 kg (CL-5610/CL-5610S main body) Approximately 0.5 kg x 2 (Converter CL-0420 for CL-5610S) |
| price |
CL-5610:
CL-5610S:
|