Skip to content

Select your region & language

Global

Region

Motor measuring device Torque Station Pro TS-8700 System

Motor basic characteristic measurement system Achieves even higher accuracy and high response measurement

  • Torque Station Pro TS-8700 System
    Torque Station Pro TS-8700 System

The Torque Station Pro TS-8700 is a motor basic characteristics measurement system with significantly improved specifications and functions.

By combining the newly adopted high-precision, high-response TH-type torque detector with the MT-type motor torque detector, measurements can be taken at a maximum sampling rate of 5120 Hz with an accuracy of ±0.1%.

Data can now be linked to the graphing software "O-Chart" and the time-series data analysis software "Oscope," improving the efficiency of measurement and data organization.

Features

Torque detector TH/TQ * Newly supported

We have added a model equipped with a TH-type torque detector to our existing lineup of MT detectors, which previously featured MD/SS-type torque detectors.
We can also accommodate custom orders for motor testing equipment equipped with TQ-type torque detectors.

High precision and high responsiveness *

The MT detector equipped with the TH-type detector has improved accuracy compared to existing units. (TH-1000/2000 units: ±0.1%)
In addition to the standard 1024 Hz, high-speed sampling of 5120 Hz is possible with an optional add-on.

Temperature measurement*, temperature trigger measurement*

This system enables 8-channel temperature measurement using T-type thermocouples. An optional temperature trigger function is available, which starts measurement at a specified temperature after a warm-up period.

Rotation angle measurement*, rotation angle sampling*

The built-in encoder pulse of the motor under test enables rotation angle measurement and angle sampling.
Furthermore, by adding an optional encoder to the MT-82 T/M** detector (with some exceptions) for cogging torque and torque ripple measurement, it becomes possible to measure rotational angle and angle sampling in 0.1° increments.

Integration with graph creation software "O-Chart" and time series data analysis software "Oscope"

The O-Chart and Oscope integration buttons allow for immediate data transfer of measurement results.
By preparing templates in O-Chart, the processing of reports and other documents can be streamlined. By transferring the data to Oscope, sound and vibration data measured simultaneously via ESUFEEL integration can be evaluated on the same time axis.

Integration with DS-3000 series ESUFEEL

By using the linked app, the measurement on our DS-3000 series ESUFEEL will start and stop in sync with the start and stop timing of measurement on the TS-8700 Torque Station Pro.

Power meter digital communication *

It can connect to power meters from other manufacturers via LAN, allowing for digital acquisition of measured values.
Our designated power meters include the following four models:

  • Yokogawa Electric Corporation: WT1800E, WT300E (using WTViewerEfree*1 Ver1.42 or later)
  • HIOKI E.E. CORPORATION: PW3390, PW3337 (using PW Communicator*2 Ver1.7.0 or later)

Selectable mounting frame and fixtures for the equipment configuration.

You can configure the device by selecting from tabletop stands, floor stands with casters, XYZ stages, slide bases, V-blocks, and L-shaped fixtures according to the size of the test specimen and the installation location. However, there are limitations on selection depending on the torque capacity of each series.

*:option
*1: WTViewerEfree is a trademark of Yokogawa Electric Corporation.
*2: PW Communicator is a trademark of HIOKI E.C.

Data integration functions and system configuration examples for Oscope, O-Chart, and ESUFEEL (DS-3200).

  • Data integration functions and system configuration examples for Oscope, O-Chart, and ESUFEEL (DS-3200).

The information on this page is based on the information available at the time of publication.
Please note that if product sales are discontinued, organizational changes are made, or specifications are changed after publication, the information may differ from the latest information.

This page is created by an automatic translation system based on the information in the Japanese version. Details