USB Microphone (Limited Quantity · No Restock))
Make your first move smarter.
The shortest route to detailed analysis—all in a single device.
A USB microphone is a sensor that allows users to easily measure and record sound by simply connecting it to the USB port of a PC or smartphone. With an integrated A/D converter built into the sensor, digital signals are output directly through the USB interface.
The dedicated recording software (USB Microphone Recorder, free of charge) enables seamless data transfer to the O-Solution analysis software for further analysis.
※Offer ends while supplies last.
Features
-
USB connectivity and bus-powered operation
-
Measurement frequency range: 20 Hz to 18.75 kHz / Maximum sound pressure level: 130 dB
-
Easy plug-and-play connection
-
Wide-range sound pressure level measurement with dual input voltage ranges (High/Low)
-
Easy recording with USB Microphone Recorder (free software)
Case study
-
"Abnormal Noise Diagnosis"for automotive dealershipsand repair shops
Instantly capture abnormal noise.
-
"Routine Inspection" of factory equipment
Pocket-sized for sound recording anywhere.
-
"Quality Check" for household appliances and precision equipment
Ideal for motor noise investigation.
-
"Embedded Applications" in industrial equipment and systems
Direct SBC Connectivity for Cost-Effective Acoustic Measurement.
-
"Acoustics Engineering Training" in educational and research institutions
Affordable enough for every student to experience real measurement.
-
"Field Data Collection" in product development
Compact and easy to carry, making it ideal for field sound recording.
Software (USB Microphone Recorder )
This software is designed for USB microphones. You can operate it by connecting a USB microphone and a computer with a USB cable. It displays and records time waveforms, and saves the recorded data to a specified folder.
Seamless integration with O-Solution analysis software
The dedicated USB microphone recorder enables smooth data transfer to O-Solution for efficient analysis.
Features
Triggered Recording Function
Recording can be started automatically when the input signal exceeds a specified sound pressure level.
The software also features the "Pre-Recording Function", which allows recording to begin several seconds before the trigger event occurs.
This makes it possible to capture sounds even before an abnormal noise is generated.
Automatic Repetitive Recording
Using the trigger function, recordings can be automatically repeated for a preset recording duration.
Case Study
Motor noise
Automatically records sounds when an abnormal noise is detected—for example, repeatedly capturing abnormal noises generated by motors.
-
-
Automatic Repetitive Recording function
Specifications
USB Microphone
| Items | Specifications |
| Response Type | Free field |
| Sampling Frequency | 11.025 kHz, 16 kHz, 22.05 kHz, 32 kHz, 44.1 kHz, 48 kHz (Fixed for iOS) |
| A/D Conversion Resolution | 16 bit |
| Frequency Characteristics | 20 to less than 100 Hz: Within ±3.0 dB 100 Hz to less than 8 kHz: Within ±2.0 dB 8 to 18.75 kHz or less: Within ±3.5 dB |
| Max. Sound Pressure Level | 130 dB or higher at 1 kHz (High range) |
| Measurement Range | High Range: 134 dB FS (Typ.) Low Range: 104 dB FS (Typ.) |
| Digital Sensitivity | High Range:232.4984 Count/Pa (140.94 Pa/FS) Low Range:7352.244 Count/Pa (4.4569 Pa/FS) |
| Self-Noise Level | 34 dB (A) or less |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | -10 to 60 °C |
| Operating/Storage Humidity | 20 to 80% RH (No condensation, no icing) |
| Connector | USB Type-C connector |
| Device Class | USB Audio Class |
| Power Supply | Bus-powered |
| Weight | Approx. 33 g (excluding cable) |
| Material/Surface Treatment | Microphone: Stainless steel Housing: Black anodized aluminium |
| Accessories | USB Type-C cable (USB A to USB C, 1 m) x 1, Instruction manual x 1 |
| Applicable Standards | RoHS: 2011/65/EU, EN IEC 63000 |
| Dimensions | Overall Length: 79 mm, microphone capsule diameter: Ø13.2 mm (1/2 in.), housing diameter: Ø19 mm |
| Outline Drawings (Unit: mm) |
![]() |
Practical features for a wide range of sound measurement applications
-
Frequency Response
-
Microphone Directivity -
USB microphone recorder Specification
| Trigger | Equipped with a One-Shot Trigger Function |
| Pre-recording* | Recording can start a few seconds before the trigger is activated. |
| Start recording | Recording can be started manually or by the Trigger Function. Continuous Automatic Recording Function is also available.* |
| Recording time | Can be configured arbitrarily. Recording can be stopped manually. |
| Language | Japanese, English, Chinese |
| Save file format | ORF file (O-Solution/binary format) WAVE file |
*Effective only when using the Trigger Function.
PC Operation Environment
| OS | Microsoft® Windows® 11 Home Microsoft® Windows® 11 Pro Microsoft® Windows® 11 Enterprise |
| CPU | Intel® Core™ i5 or higher grade and 13th Generation or later generation 12 cores and 16 threads or more, and 1.9 GHz or more base clock |
| Memory | Minimum 16 GB |
| Storage | Minimum free space 5 GB |
| Display | Minimum 1920 × 1080 |
*Connection with all commercially available personal computers is not guaranteed. For example, even if the operating environment is met, this system may not operate properly due to the physical shape, other installed software, or peripheral devices.
*Microsoft® Windows® are registered trademarks of Microsoft Corporation in the United States and other countries. USB Type-C® and USB-C® are registered trademarks of USB Implementers Forum. Other product names are trademarks or registered trademarks of each individual company. The copyrights are reserved by each individual company.
Related product
-
High performance Sound Level Meter LA-7000 series -
Sound level meterLA-1411/1441A/4441A -
Sound Calibrator SC-2120A/SC-2500A/SC-2600 -
Sound and Vibration Analysis system O-Solution DS-5000 -
Measurement/Analysis software O-Solution -
O-Solution DS-5000 Sound Power Level Measurement SystemNEW -
Sound Quality Evaluation Function O-Solution OS-0525 -
Fluctuation Sound Analysis Function O-Solution OS-0526 -
Time Frequency Analysis Function O-Solution OS-0527